The main factors limiting the measurement distance of DAS system and improvement methods

With the increasing application of distributed acoustic sensing (DAS) in long-distance scenarios such as oil/gas pipeline monitoring and perimeter security, critical challenges persist in mitigating signal attenuation, noise accumulation, and distance-dependent degradation of sensing accuracy, while existing approaches struggle to simultaneously achieve ultra-long- range detection with high sensitivity and optimal optical signal-to-noise ratio (OSNR). The article analyzes several factors limiting the sensing distance in DAS systems, including system sensitivity, dynamic range, and optical signal-to-noise ratio (OSNR). A 150 km fiber-optic sensing experimental setup was constructed, employing distributed fiber Raman amplifiers to suppress the dynamic range of echo signals. By adopting coherent signal split-beam sampling and weak-strong signal splicing techniques to enhance the system's dynamic range, combined with fiber Bragg grating filtering to achieve high SNR, the system realized a maximum effective sensing distance of 125 km.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1117/12.3071894
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The main factors limiting the measurement distance of DAS system and improvement methods

Zhaoyun Li, Yu Yue, Xiaodong Liang, Wenje Han et al.
Advanced Fiber Optic Sensors
article

The main factors limiting the measurement distance of DAS system and improvement methods

Zhaoyun Li, Yu Yue, Xiaodong Liang, Wenje Han, Tao Ju, Jia Luo, Tian Li, Rong Sun
article en

Abstract

With the increasing application of distributed acoustic sensing (DAS) in long-distance scenarios such as oil/gas pipeline monitoring and perimeter security, critical challenges persist in mitigating signal attenuation, noise accumulation, and distance-dependent degradation of sensing accuracy, while existing approaches struggle to simultaneously achieve ultra-long- range detection with high sensitivity and optimal optical signal-to-noise ratio (OSNR). The article analyzes several factors limiting the sensing distance in DAS systems, including system sensitivity, dynamic range, and optical signal-to-noise ratio (OSNR). A 150 km fiber-optic sensing experimental setup was constructed, employing distributed fiber Raman amplifiers to suppress the dynamic range of echo signals. By adopting coherent signal split-beam sampling and weak-strong signal splicing techniques to enhance the system's dynamic range, combined with fiber Bragg grating filtering to achieve high SNR, the system realized a maximum effective sensing distance of 125 km.

Heinz Optical Engineering (United States) (US), Guilin University of Electronic Technology (CN)
Openalex Percentile: Top 79%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.