Random Temporal Signals (RATS) Method for Measuring High-Reflectance Coatings via a Cavity Ring-Down Configuration

Manufacturing surfaces with high-reflectance (HR) coatings is important for applications where energy losses need to be minimized, such as laser resonators or calibration systems. However, measuring reflectances <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$R&gt;99.99 \%$</tex> is already problematic for a standard photometer. Therefore, multi-reflectance techniques such as cavity ring-down (CRD) measurements are used. Cavities can have different configurations, and each of them brings specific advantages. Nevertheless, typically, HR-CRD systems use a time-resolved approach comprising pulses entering the cavity and detecting cavity response (decay curve <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$I_{\mathrm{D}}$</tex>) represented with lifetime and corresponding reflectance [1]. However, the use of pulses has several drawbacks imposed by the fact that only one pulse must be present in the cavity. This restriction sets a limit to the pulse repetition rate, which has to be very low for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$R&gt;99.9995 \%$</tex>. In addition, the standard CRD experiment needs to find a compromise between the need for a high input pulse energy to overcome high losses during the pulse input into the cavity and the laser-induced damage threshold of the entrance cavity mirror. As a result, a high number of laser pulses with a low repetition rate are averaged, resulting in long acquisition times reaching several hours.

Authors

Institutions

Publication Details

Published
2025-06-23
DOI
https://doi.org/10.1109/cleo/europe-eqec65582.2025.11109874
Primary Topic
Surface Roughness and Optical Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Random Temporal Signals (RATS) Method for Measuring High-Reflectance Coatings via a Cavity Ring-Down Configuration

Karel Žídek, Jiří Junek
Surface Roughness and Optical Measurements
article

Random Temporal Signals (RATS) Method for Measuring High-Reflectance Coatings via a Cavity Ring-Down Configuration

Karel Žídek, Jiří Junek
article en

Abstract

Manufacturing surfaces with high-reflectance (HR) coatings is important for applications where energy losses need to be minimized, such as laser resonators or calibration systems. However, measuring reflectances <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$R&gt;99.99 \%$</tex> is already problematic for a standard photometer. Therefore, multi-reflectance techniques such as cavity ring-down (CRD) measurements are used. Cavities can have different configurations, and each of them brings specific advantages. Nevertheless, typically, HR-CRD systems use a time-resolved approach comprising pulses entering the cavity and detecting cavity response (decay curve <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$I_{\mathrm{D}}$</tex>) represented with lifetime and corresponding reflectance [1]. However, the use of pulses has several drawbacks imposed by the fact that only one pulse must be present in the cavity. This restriction sets a limit to the pulse repetition rate, which has to be very low for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$R&gt;99.9995 \%$</tex>. In addition, the standard CRD experiment needs to find a compromise between the need for a high input pulse energy to overcome high losses during the pulse input into the cavity and the laser-induced damage threshold of the entrance cavity mirror. As a result, a high number of laser pulses with a low repetition rate are averaged, resulting in long acquisition times reaching several hours.

Czech Academy of Sciences, Institute of Plasma Physics (CZ)
Openalex Percentile: Top 77%
Surface Roughness and Optical Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Random Temporal Signals (RATS) Method for Measuring High-Reflectance Coatings via a Cavity Ring-Down Configuration — Karel Žídek, Jiří Junek · (2025) | TGRS Research Map | TGRS