Vascular Intima‐Biomimetic Bilayer Hydrogel Coating of Central Venous Catheters with Dual‐Modal Anti‐Coagulation and Self‐Adaptive Immunomodulation

Abstract Although central venous catheters (CVCs) exhibit promising hemocompatibility and interfacial stability, their clinical applications are constrained by the inability to counteract thrombus and acute inflammation. Herein, a novel vascular intima‐biomimetic bilayered hydrogel coating is designed to mitigate clinical thrombotic and inflammatory complications. Firstly, passive anti‐coagulation shield established by hydrophilic groups orchestrated robust hydration shells, which achieved non‐specific adhesion resistance against blood compositions. Active anti‐coagulation mode was simultaneously established by dynamic thiol/sulfonic redox moieties, realizing synergetic inhibition effects on the activity of coagulation factors and self‐activation of coagulation cascade. Secondly, the hydrogel presented a free radicals‐scavenging rate of 79.42% ± 1.34% coupled with macrophage phenotype remodeling, effectively constructing an ideal anti‐bacterial microenvironment for repair of oxidative stress‐mediated endothelial damage. More interestingly, such biomimetic bilayered hydrogel coating achieved exceptional adhesion stability toward CVCs, meanwhile its vascular intima‐mimetic modulus reduced mismatch‐induced endothelial injury, thereby ensuring long‐term interfacial integrity and implant safety. According to in vivo and ex vivo results of rat subcutaneous implantation and rabbit arteriovenous (AV) shunts model, the coating significantly decreased catheter occlusion rate (0.90% ± 0.64%), suppressed F1+2 accumulation, and inhibited TNF‐α expression. Overall, the hydrogel coating with synergetic anti‐coagulant/anti‐inflammatory functionalities established an effective bio‐interfacial for clinical indwelling device safety, demonstrating particularly promising applications.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2025-08-15
DOI
https://doi.org/10.1002/adfm.202511029
Citations
2
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
5.03

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vascular Intima‐Biomimetic Bilayer Hydrogel Coating of Central Venous Catheters with Dual‐Modal Anti‐Coagulation and Self‐Adaptive Immunomodulation

Wenjing Song, Yueqing Chen, Gaoxing Pan, Jinfeng Wu et al.
2 citations
Advanced Functional Materials
Central Venous Catheters and Hemodialysis
5.03
article

Vascular Intima‐Biomimetic Bilayer Hydrogel Coating of Central Venous Catheters with Dual‐Modal Anti‐Coagulation and Self‐Adaptive Immunomodulation

Wenjing Song, Yueqing Chen, Gaoxing Pan, Jinfeng Wu, Renjie Ruan, Zhilu Yang, Fenglu Li, Peijie Xiao, Xiaohui Mou, Jin Zhang, Xiaoyu Hu, Lu Xu, Yanyun Liu
article en
2 citations

Abstract

Abstract Although central venous catheters (CVCs) exhibit promising hemocompatibility and interfacial stability, their clinical applications are constrained by the inability to counteract thrombus and acute inflammation. Herein, a novel vascular intima‐biomimetic bilayered hydrogel coating is designed to mitigate clinical thrombotic and inflammatory complications. Firstly, passive anti‐coagulation shield established by hydrophilic groups orchestrated robust hydration shells, which achieved non‐specific adhesion resistance against blood compositions. Active anti‐coagulation mode was simultaneously established by dynamic thiol/sulfonic redox moieties, realizing synergetic inhibition effects on the activity of coagulation factors and self‐activation of coagulation cascade. Secondly, the hydrogel presented a free radicals‐scavenging rate of 79.42% ± 1.34% coupled with macrophage phenotype remodeling, effectively constructing an ideal anti‐bacterial microenvironment for repair of oxidative stress‐mediated endothelial damage. More interestingly, such biomimetic bilayered hydrogel coating achieved exceptional adhesion stability toward CVCs, meanwhile its vascular intima‐mimetic modulus reduced mismatch‐induced endothelial injury, thereby ensuring long‐term interfacial integrity and implant safety. According to in vivo and ex vivo results of rat subcutaneous implantation and rabbit arteriovenous (AV) shunts model, the coating significantly decreased catheter occlusion rate (0.90% ± 0.64%), suppressed F1+2 accumulation, and inhibited TNF‐α expression. Overall, the hydrogel coating with synergetic anti‐coagulant/anti‐inflammatory functionalities established an effective bio‐interfacial for clinical indwelling device safety, demonstrating particularly promising applications.

Advanced Functional MaterialsVol. 36(7)
Dongguan People’s Hospital (CN), Fujian Provincial Hospital (CN), Fuzhou University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 5%
Central Venous Catheters and Hemodialysis
5.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.