Picosecond Contrast Improvement for PW Class Lasers Based on Modified Stretcher Design

The picosecond contrast is an outmost parameter for multi-PW laser systems. The presence of tens of picosecond pedestal prior to the main pulse in multi-PW class laser system could lead to damage of the target as it can reach intensity on target higher than 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">14</sup>W/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. It has been demonstrated that the convex mirror within the Offner stretcher of those laser systems is the main contributor to this pedestal [1]. To reduce this effect, ultralow roughness mirrors have been implemented in some laser systems [2].

Authors

Institutions

Publication Details

Published
2025-06-23
DOI
https://doi.org/10.1109/cleo/europe-eqec65582.2025.11110753
Citations
1
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Picosecond Contrast Improvement for PW Class Lasers Based on Modified Stretcher Design

Bruno LeGarrec, Alain Pellegrina, E. Gaul, S. Pasternak et al.
1 citations
Laser-Plasma Interactions and Diagnostics
article

Picosecond Contrast Improvement for PW Class Lasers Based on Modified Stretcher Design

Bruno LeGarrec, Alain Pellegrina, E. Gaul, S. Pasternak, Alexandru Toma, C. Derycke, Dimitrios Papadopoulos, Michel Charbonneau, Saidbek Norbaev, Olivier Chalus, N. Lebas, Fabrice Mathieu, Ioan Dăncuş, G. Cojocaru, Sandrine Ricaud, P. Audebert, Salim Ferhat
article en
1 citations

Abstract

The picosecond contrast is an outmost parameter for multi-PW laser systems. The presence of tens of picosecond pedestal prior to the main pulse in multi-PW class laser system could lead to damage of the target as it can reach intensity on target higher than 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">14</sup>W/cm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup>. It has been demonstrated that the convex mirror within the Offner stretcher of those laser systems is the main contributor to this pedestal [1]. To reduce this effect, ultralow roughness mirrors have been implemented in some laser systems [2].

Centre National de la Recherche Scientifique (FR), Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR), Thales (Australia) (AU), Sorbonne Université (FR), Laboratoire pour l'Utilisation des Lasers Intenses (FR), Thales (France) (FR), Extreme Light Infrastructure - Nuclear Physics (RO), Marvell (Israel) (IL)
Affordable and clean energy
Openalex Percentile: Top 91%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.