Differences in feasibility and outcomes of catheter ablation using robotic magnetic navigation in patients with congenital heart disease depending on the complexity of the defect

Introduction Robotic magnetic navigation (RMN) allows catheter ablation in the presence of a difficult cardiac anatomy such as congenital heart diseases (CHD). The objective of this study is to evaluate the feasibility, efficacy and safety of this procedure depending on the complexity of defect. Methods Patients with CHD, who underwent catheter ablation of cardiac arrhythmia with the use of RMN, were included. Patients baseline characteristics, procedural data, periprocedural complications and acute success rates were obtained. Efficacy of the ablation was evaluated during follow-up in the outpatient clinic with the use of 24-hour Holter monitoring. Results Study population consisted of 38 patients (26 males) with a median age of 36.8 (IQR 30.8-39.6). Surgically corrected transposition of the great arteries was the most common CHD, that occurred in 14 patients (36.8%). Nineteen patients (50.0%) had more than one congenital defect. Atrial flutter was the most common arrythmia ablated in 21 procedures (55.3%). Mean procedural time was 322.9 minutes (SD 99.3), median radiation dose and radiation time were 2.4 mGym 2 (IQR 1.3-4.4) and 14.0 minutes (IQR 9.5-30.4), respectively. Acute arrhythmia cessation was observed during 81.6% of procedures. Major complications were noted in 2 cases (5.3%). Median time from the ablation to follow-up was 5.4 months (IQR 3.4-9.3). Arrhythmia recurrence was observed in 7 cases (18.4%). Conclusions RMN is a valuable tool for catheter ablation for arrhythmias in patients with congenital heart disease and complex anatomy.

Authors

Institutions

Publication Details

Published
2025-08-17
DOI
https://doi.org/10.22541/au.175543205.53544751/v1
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differences in feasibility and outcomes of catheter ablation using robotic magnetic navigation in patients with congenital heart disease depending on the complexity of the defect

Magdalena Lipczyńska, Grzegorz Warmiński, Robert Bodalski, Maria Bilińska et al.
Congenital Heart Disease Studies
article

Differences in feasibility and outcomes of catheter ablation using robotic magnetic navigation in patients with congenital heart disease depending on the complexity of the defect

Magdalena Lipczyńska, Grzegorz Warmiński, Robert Bodalski, Maria Bilińska, Filip Machaj, Ewa Warchoł-Celińska, Łukasz Jan Szumowski, Jakub Malinowski, Mirosław Kowalski, Andrzej Hasiec, Piotr Urbanek, Michał Orczykowski
article en

Abstract

Introduction Robotic magnetic navigation (RMN) allows catheter ablation in the presence of a difficult cardiac anatomy such as congenital heart diseases (CHD). The objective of this study is to evaluate the feasibility, efficacy and safety of this procedure depending on the complexity of defect. Methods Patients with CHD, who underwent catheter ablation of cardiac arrhythmia with the use of RMN, were included. Patients baseline characteristics, procedural data, periprocedural complications and acute success rates were obtained. Efficacy of the ablation was evaluated during follow-up in the outpatient clinic with the use of 24-hour Holter monitoring. Results Study population consisted of 38 patients (26 males) with a median age of 36.8 (IQR 30.8-39.6). Surgically corrected transposition of the great arteries was the most common CHD, that occurred in 14 patients (36.8%). Nineteen patients (50.0%) had more than one congenital defect. Atrial flutter was the most common arrythmia ablated in 21 procedures (55.3%). Mean procedural time was 322.9 minutes (SD 99.3), median radiation dose and radiation time were 2.4 mGym 2 (IQR 1.3-4.4) and 14.0 minutes (IQR 9.5-30.4), respectively. Acute arrhythmia cessation was observed during 81.6% of procedures. Major complications were noted in 2 cases (5.3%). Median time from the ablation to follow-up was 5.4 months (IQR 3.4-9.3). Arrhythmia recurrence was observed in 7 cases (18.4%). Conclusions RMN is a valuable tool for catheter ablation for arrhythmias in patients with congenital heart disease and complex anatomy.

National Multiple Sclerosis Society (US)
Openalex Percentile: Top 70%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.