Spectral Regulation in Cs<sub>2</sub>PtCl<sub>6</sub> Double Perovskite via Low-Temperature and High-Pressure Engineering for Advanced Optical Thermometry and Manometry

To build a bifunctional luminescent platform for optical thermometry and manometry, the Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite was synthesized. Upon 468 nm excitation, the designed compound emitted bright red light centered at ≈675 nm, originating from the <sup>3</sup>T<sub>1g</sub>,<sup>3</sup>T<sub>2g</sub> → <sup>1</sup>A<sub>1g</sub> transition of Pt<sup>4+</sup>, whose fluorescence intensity and bandwidth are highly temperature dependent. Moreover, the temperature-dependent decay curves of the developed Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite were measured to explore its application in optical thermometry, of which its maximum relative sensor sensitivity is 1.21% K<sup>-1</sup>, with the operation range of 100-310 K. Furthermore, the impact of pressure on the phase structure and luminescence behaviors of the Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite was also discussed. The pressure-dependent Raman spectra clarified that the synthesized compound possesses a stable phase structure at high pressure. Furthermore, Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite exhibits distinct spectral blue-shift at high pressure. Importantly, as pressure increases (i.e., 0-5.67 GPa), the emission band centroid and full width at half-maximum (fwhm) are both linearly dependent on pressure, resulting in high pressure sensitivities of dλ/d<i>p</i> = 7.19 nm/GPa and d<i>fwhm</i>/d<i>p</i> = 4.95 nm/GPa, respectively. Our finding manifests that the luminescence characteristics of the Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite can be efficiently regulated via low temperature and high pressure, enabling its applications in optical thermometry and manometry.

Authors

Institutions

Publication Details

Journal
ACS Applied Materials & Interfaces
Published
2025-08-22
DOI
https://doi.org/10.1021/acsami.5c12347
Citations
7
Primary Topic
Perovskite Materials and Applications
Type
article
Field-Weighted Citation Impact
5.11

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectral Regulation in Cs2PtCl6 Double Perovskite via Low-Temperature and High-Pressure Engineering for Advanced Optical Thermometry and Manometry

Przemysław Woźny, Laihui Luo, Marcin Runowski, Zingway Pei et al.
7 citations
ACS Applied Materials & Interfaces
Perovskite Materials and Applications
5.11
article

Spectral Regulation in Cs2PtCl6 Double Perovskite via Low-Temperature and High-Pressure Engineering for Advanced Optical Thermometry and Manometry

Przemysław Woźny, Laihui Luo, Marcin Runowski, Zingway Pei, Peng Du, Xuanyu Ge
article en
7 citations

Abstract

To build a bifunctional luminescent platform for optical thermometry and manometry, the Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite was synthesized. Upon 468 nm excitation, the designed compound emitted bright red light centered at ≈675 nm, originating from the <sup>3</sup>T<sub>1g</sub>,<sup>3</sup>T<sub>2g</sub> → <sup>1</sup>A<sub>1g</sub> transition of Pt<sup>4+</sup>, whose fluorescence intensity and bandwidth are highly temperature dependent. Moreover, the temperature-dependent decay curves of the developed Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite were measured to explore its application in optical thermometry, of which its maximum relative sensor sensitivity is 1.21% K<sup>-1</sup>, with the operation range of 100-310 K. Furthermore, the impact of pressure on the phase structure and luminescence behaviors of the Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite was also discussed. The pressure-dependent Raman spectra clarified that the synthesized compound possesses a stable phase structure at high pressure. Furthermore, Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite exhibits distinct spectral blue-shift at high pressure. Importantly, as pressure increases (i.e., 0-5.67 GPa), the emission band centroid and full width at half-maximum (fwhm) are both linearly dependent on pressure, resulting in high pressure sensitivities of dλ/d<i>p</i> = 7.19 nm/GPa and d<i>fwhm</i>/d<i>p</i> = 4.95 nm/GPa, respectively. Our finding manifests that the luminescence characteristics of the Cs<sub>2</sub>PtCl<sub>6</sub> double perovskite can be efficiently regulated via low temperature and high pressure, enabling its applications in optical thermometry and manometry.

ACS Applied Materials & InterfacesVol. 17(35)
Ningbo University (CN), Adam Mickiewicz University in Poznań (PL)
Narodowe Centrum Nauki, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 4%
Perovskite Materials and Applications
5.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.