Parameter Optimization of MOSA for MVDC Circuit Breakers Based on Required Performance Using Short-Circuit Current Test-Bed Simulation

Medium Voltage Direct Current (MVDC) systems are increasingly connected with renewable energy sources and DC loads for more flexible and efficient power transmission. Stable operation requires minimizing fault impacts and rapid fault isolation. This necessitates effective protection strategies, including fast-acting MVDC circuit breakers with optimized characteristics like fast fault detection, current zero-crossing mechanisms, high dielectric strength, and large energy absorption capability. The absorption energy of Metal Oxide Surge Arresters (MOSAs) in MVDC circuit breakers is influenced by system cable characteristics and increased when reactors are used to limit fault currents, requiring optimization. This paper presents a shortcircuit current test-bed using a low-frequency AC source to optimize MOSA for MVDC circuit breakers. Simulations in PSCAD/EMTDC were performed for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$21 \text{kV} / 1 \text{MJ}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$42 \text{kV} / 2 \text{MJ}$</tex> cases, analyzing MOSA absorption energy.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/eic63069.2025.11123374
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parameter Optimization of MOSA for MVDC Circuit Breakers Based on Required Performance Using Short-Circuit Current Test-Bed Simulation

Yu-Jin Kwak, Il Keun Kwon, Bang-Wook Lee, Jeong-Cheol Lee
HVDC Systems and Fault Protection
article

Parameter Optimization of MOSA for MVDC Circuit Breakers Based on Required Performance Using Short-Circuit Current Test-Bed Simulation

Yu-Jin Kwak, Il Keun Kwon, Bang-Wook Lee, Jeong-Cheol Lee
article en

Abstract

Medium Voltage Direct Current (MVDC) systems are increasingly connected with renewable energy sources and DC loads for more flexible and efficient power transmission. Stable operation requires minimizing fault impacts and rapid fault isolation. This necessitates effective protection strategies, including fast-acting MVDC circuit breakers with optimized characteristics like fast fault detection, current zero-crossing mechanisms, high dielectric strength, and large energy absorption capability. The absorption energy of Metal Oxide Surge Arresters (MOSAs) in MVDC circuit breakers is influenced by system cable characteristics and increased when reactors are used to limit fault currents, requiring optimization. This paper presents a shortcircuit current test-bed using a low-frequency AC source to optimize MOSA for MVDC circuit breakers. Simulations in PSCAD/EMTDC were performed for <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$21 \text{kV} / 1 \text{MJ}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$42 \text{kV} / 2 \text{MJ}$</tex> cases, analyzing MOSA absorption energy.

Hanyang University (KR), Anyang University (KR)
Affordable and clean energy
Openalex Percentile: Top 79%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.