Design and Experimental Study of Parallel Hip Joint

Currently, humanoid robots are widely used in human-machine interaction and service fields. However, most humanoid robots use serial hip joint mechanisms, which face insufficient drive under high loads, leading to interference during movement and unnatural gait. This paper proposes a novel parallel hip joint mechanism. By combining drive units in the sagittal and coronal planes in parallel, higher torque output can be achieved in two degrees of freedom without changing the drive unit model. First, the parallel hip joint structure is designed, kinematics and dynamics models are established, and a simulation model is built for verification. Second, key parameters are optimized using the NSGA-II algorithm, and overall structural design is completed through strength verification. Finally, experimental validation of the proposed parallel hip joint mechanism shows significantly better torque output performance compared to traditional serial hip joints. This parallel hip joint mechanism has broad application prospects in humanoid robots and other service robots.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icma65362.2025.11120665
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Experimental Study of Parallel Hip Joint

Da‐Liang Zhu, Quan Wang, Juan Li, Gai Liu et al.
Orthopaedic implants and arthroplasty
article

Design and Experimental Study of Parallel Hip Joint

Da‐Liang Zhu, Quan Wang, Juan Li, Gai Liu, Weida Li, Yongqi Zhu
article en

Abstract

Currently, humanoid robots are widely used in human-machine interaction and service fields. However, most humanoid robots use serial hip joint mechanisms, which face insufficient drive under high loads, leading to interference during movement and unnatural gait. This paper proposes a novel parallel hip joint mechanism. By combining drive units in the sagittal and coronal planes in parallel, higher torque output can be achieved in two degrees of freedom without changing the drive unit model. First, the parallel hip joint structure is designed, kinematics and dynamics models are established, and a simulation model is built for verification. Second, key parameters are optimized using the NSGA-II algorithm, and overall structural design is completed through strength verification. Finally, experimental validation of the proposed parallel hip joint mechanism shows significantly better torque output performance compared to traditional serial hip joints. This parallel hip joint mechanism has broad application prospects in humanoid robots and other service robots.

Soochow University (TW), Soochow University (CN)
Openalex Percentile: Top 65%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.