Implementation of Precise Temperature Measuring System Using Different-Arm Asymmetric Differential Bridge

To solve problems that conventional temperature measuring systems have poor temperature measuring accuracy, a novel precise temperature measuring system using Different-arm Asymmetric Differential Bridge (DADB) is proposed. Firstly, key factors of Output Nonlinearity (ON) of conventional temperature measuring circuit are studied by analyzing output characteristic, and DADB plus its parameter optimal selection are established to suppress ON and improve sensitivity. Secondly, AD module with synchronous sampling and holding function is used to eliminate Nonsynchronous Sampling Errors (NSE), and Forward Reverse Excitation Control (FREC) is designed to calibrate Measuring Deviations (MD) caused by differential amplifier's offset voltage. Last, precise temperature measuring system is implemented, and it is tested in experiments. The experimental results show that its temperature measuring accuracy is much better than ±0.001°C in 0~118°C, and it is widely used in national production and so on.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icma65362.2025.11120807
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of Precise Temperature Measuring System Using Different-Arm Asymmetric Differential Bridge

Jianhua Cheng, Hao Tian, Bing Qi, Yuxuan Xiao
Flow Measurement and Analysis
article

Implementation of Precise Temperature Measuring System Using Different-Arm Asymmetric Differential Bridge

Jianhua Cheng, Hao Tian, Bing Qi, Yuxuan Xiao
article en

Abstract

To solve problems that conventional temperature measuring systems have poor temperature measuring accuracy, a novel precise temperature measuring system using Different-arm Asymmetric Differential Bridge (DADB) is proposed. Firstly, key factors of Output Nonlinearity (ON) of conventional temperature measuring circuit are studied by analyzing output characteristic, and DADB plus its parameter optimal selection are established to suppress ON and improve sensitivity. Secondly, AD module with synchronous sampling and holding function is used to eliminate Nonsynchronous Sampling Errors (NSE), and Forward Reverse Excitation Control (FREC) is designed to calibrate Measuring Deviations (MD) caused by differential amplifier's offset voltage. Last, precise temperature measuring system is implemented, and it is tested in experiments. The experimental results show that its temperature measuring accuracy is much better than ±0.001°C in 0~118°C, and it is widely used in national production and so on.

Harbin Engineering University (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 75%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.