Comparison of New and Old High Voltage Diamond Coil Electrical Insulation Performance for Hydro Electric Generators

This paper compares high-voltage electrical coils from hydroelectric generators after <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{3 8}$</tex> years of service with newly manufactured replacement coils. The original coils are part of the US Army Corps of Engineers' renovation of the Chief Joseph Dam in Washington State, with 16 generator units (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$92,920 \text{kVA}, 13,800 ~\mathrm{V}$</tex>) being rewound. Preformed Windings will supply the new coils, designed to sustain decades of renewable energy production. With the average age of hydroelectric power station in the U.S. approaching 50 years, this paper is to create a reference for the industry of the expected benefits that can be achieved by rewinding of the fleet using resin rich coils manufactured with modern techniques.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/eic63069.2025.11123364
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of New and Old High Voltage Diamond Coil Electrical Insulation Performance for Hydro Electric Generators

S. Muthukumaran, Ratanak So, Jason Floyd, A. Thomas et al.
High voltage insulation and dielectric phenomena
article

Comparison of New and Old High Voltage Diamond Coil Electrical Insulation Performance for Hydro Electric Generators

S. Muthukumaran, Ratanak So, Jason Floyd, A. Thomas, Martyn Widdowson, Ben Maynard, Kyle Hargreaves
article en

Abstract

This paper compares high-voltage electrical coils from hydroelectric generators after <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{3 8}$</tex> years of service with newly manufactured replacement coils. The original coils are part of the US Army Corps of Engineers' renovation of the Chief Joseph Dam in Washington State, with 16 generator units (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$92,920 \text{kVA}, 13,800 ~\mathrm{V}$</tex>) being rewound. Preformed Windings will supply the new coils, designed to sustain decades of renewable energy production. With the average age of hydroelectric power station in the U.S. approaching 50 years, this paper is to create a reference for the industry of the expected benefits that can be achieved by rewinding of the fleet using resin rich coils manufactured with modern techniques.

United States Army Corps of Engineers (US)
U.S. Army Corps of Engineers
Affordable and clean energy
Openalex Percentile: Top 84%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of New and Old High Voltage Diamond Coil Electrical Insulation Performance for Hydro Electric Generators — S. Muthukumaran, Ratanak So, et al. · (2025) | TGRS Research Map | TGRS