Development and Validation of a Real-Time Force/Torque Sensing System for Precision Acupuncture Robots

Acupuncture transmits the treatment of systemic diseases through meridians and acupoints, relying on specific operation techniques. However, traditional acupuncture has some problems such as strong subjectivity in acupoint selection and difficulty in technical standardization. With the development of artificial intelligence and medical robot technology, acupuncture treatment has a new opportunity.This study developed a model for the acupuncture robot's end effector based on SolidWorks, establishing a complete control mathematical model that includes the motor drive and needle contact process. The control system simulation design and physical prototype debugging were completed. By calibrating the coaxial six-axis force sensor with the force and torque at the needle tip, a compensation mathematical model was established to achieve force correction at the end effector. This research provides technical support and theoretical foundation for the automation and standardization of acupuncture operations.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icma65362.2025.11120789
Primary Topic
Robot Manipulation and Learning
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Real-Time Force/Torque Sensing System for Precision Acupuncture Robots

Lin Xu, Yujie Zhang, Linshuai Zhang, Dai Qiu et al.
Robot Manipulation and Learning
article

Development and Validation of a Real-Time Force/Torque Sensing System for Precision Acupuncture Robots

Lin Xu, Yujie Zhang, Linshuai Zhang, Dai Qiu, Tao Jiang, Xin Tian, Zhihang Yuan, Shuoxin Gu
article en

Abstract

Acupuncture transmits the treatment of systemic diseases through meridians and acupoints, relying on specific operation techniques. However, traditional acupuncture has some problems such as strong subjectivity in acupoint selection and difficulty in technical standardization. With the development of artificial intelligence and medical robot technology, acupuncture treatment has a new opportunity.This study developed a model for the acupuncture robot's end effector based on SolidWorks, establishing a complete control mathematical model that includes the motor drive and needle contact process. The control system simulation design and physical prototype debugging were completed. By calibrating the coaxial six-axis force sensor with the force and torque at the needle tip, a compensation mathematical model was established to achieve force correction at the end effector. This research provides technical support and theoretical foundation for the automation and standardization of acupuncture operations.

Chengdu University of Information Technology (CN), Chengdu University (CN), Chengdu University of Traditional Chinese Medicine (CN)
Department of Science and Technology of Sichuan Province, Natural Science Foundation of Sichuan Province, National College Students Innovation and Entrepreneurship Training Program
Affordable and clean energy
Openalex Percentile: Top 74%
Robot Manipulation and Learning
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Validation of a Real-Time Force/Torque Sensing System for Precision Acupuncture Robots — Lin Xu, Yujie Zhang, et al. · (2025) | TGRS Research Map | TGRS