The Influence of Polarity Reversal on Leakage Current in XLPE Samples

To ensure the effectiveness of insulation in MVAC cables and to facilitate multiphysics finite element method (FEM) simulations for DC applications, it is crucial to evaluate the electrical properties of insulation materials at DC. In this regard, a critical aspect of this assessment is DC conductivity, which is typically determined through leakage current (LC) measurements. In this contribution, plate samples taken from 12/20 kV and 19/33 kV XLPE MVAC cables are utilised to conduct LC measurements. By using line commutated converter (LCC) technologies polarity reversals (PR) are performed to control the load flow of the DC transmission or distribution system. Measuring LC during PR is essential for assessing the reliability of the cable insulation. This study, therefore, presents findings from LC measurements at constant electric and thermal stress, with PR cycles after every 6 hours. This provides valuable insights for the development and optimisation of MVDC cables.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/eic63069.2025.11123248
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of Polarity Reversal on Leakage Current in XLPE Samples

Patrik Ratheiser, Brian Stewart, Uwe Schichler, S. Shahtaj
High voltage insulation and dielectric phenomena
article

The Influence of Polarity Reversal on Leakage Current in XLPE Samples

Patrik Ratheiser, Brian Stewart, Uwe Schichler, S. Shahtaj
article en

Abstract

To ensure the effectiveness of insulation in MVAC cables and to facilitate multiphysics finite element method (FEM) simulations for DC applications, it is crucial to evaluate the electrical properties of insulation materials at DC. In this regard, a critical aspect of this assessment is DC conductivity, which is typically determined through leakage current (LC) measurements. In this contribution, plate samples taken from 12/20 kV and 19/33 kV XLPE MVAC cables are utilised to conduct LC measurements. By using line commutated converter (LCC) technologies polarity reversals (PR) are performed to control the load flow of the DC transmission or distribution system. Measuring LC during PR is essential for assessing the reliability of the cable insulation. This study, therefore, presents findings from LC measurements at constant electric and thermal stress, with PR cycles after every 6 hours. This provides valuable insights for the development and optimisation of MVDC cables.

University of Strathclyde (GB), Graz University of Technology (AT)
Openalex Percentile: Top 84%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Influence of Polarity Reversal on Leakage Current in XLPE Samples — Patrik Ratheiser, Brian Stewart, et al. · (2025) | TGRS Research Map | TGRS