Evaluating Turn Insulation Degradation Using Sweep Frequency Response Analysis

Turn insulation in stator multiturn coils is often involved in machine failures. To date, however, there are no tests for determining the long-term performance of turn insulation. Conventional diagnostic tests (partial discharge (DP) and dissipation factor (DF) measurements) are not accurate for the detection of turn insulation degradation. Sweep Frequency Response Analysis (SFRA), based on analysis of winding impedance in the frequency domain, has been used for more than 40 years to diagnose power transformer windings, and its application in rotating machines is currently the subject of research. The aim of this study, is to evaluate the SFRA capability to assess turn insulation degradation by the insertion of fault resistances between turns at three locations on a spare coil. SFRA measurements were compared to a numerical simulation using an RLC model representative of the stator coil.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.1109/eic63069.2025.11123414
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Turn Insulation Degradation Using Sweep Frequency Response Analysis

Éric David, Yoon Duk Seol, Hélène Provencher, Marie-Rosine Djuidje Kamdoum et al.
2 links
Engineering Applied Research
article

Evaluating Turn Insulation Degradation Using Sweep Frequency Response Analysis

Éric David, Yoon Duk Seol, Hélène Provencher, Marie-Rosine Djuidje Kamdoum, Youness Kechaf
article en

Abstract

Turn insulation in stator multiturn coils is often involved in machine failures. To date, however, there are no tests for determining the long-term performance of turn insulation. Conventional diagnostic tests (partial discharge (DP) and dissipation factor (DF) measurements) are not accurate for the detection of turn insulation degradation. Sweep Frequency Response Analysis (SFRA), based on analysis of winding impedance in the frequency domain, has been used for more than 40 years to diagnose power transformer windings, and its application in rotating machines is currently the subject of research. The aim of this study, is to evaluate the SFRA capability to assess turn insulation degradation by the insertion of fault resistances between turns at three locations on a spare coil. SFRA measurements were compared to a numerical simulation using an RLC model representative of the stator coil.

X-Fab (Germany) (DE), Xuzhou Construction Machinery Group (China) (CN), Hydro-Québec (CA)
Openalex Percentile: Top 77%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.