An Automatic Calibration System for Impedance Head

In order to solve the problems of low efficiency of manual impedance head calibration, such as heavy workload and complex data processing, an automatic calibration system is introduced in this paper. The system, developed in accordance with the ISO 16063-11 standard, integrates a laser interferometer, a signal excitation unit, and a data acquisition module, and is controlled by LabVIEW software. The system uses the sine approximation method to calibrate the sensitivity of acceleration and force. It supports multi-point measurement and automatically generates numerical and graphical reports. Experiments on Brüel & Kjær 8001 impedance head were carried out and preliminary results show that the system has high accuracy, repeatability and operational efficiency. More verification experiments are needed in the future for routine calibration work.

Authors

Institutions

Publication Details

Published
2025-08-03
DOI
https://doi.org/10.1109/icma65362.2025.11120805
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Automatic Calibration System for Impedance Head

Bo Zhong, Chenguang Cai, Xiujuan Feng, Hongbo Hu et al.
Sensor Technology and Measurement Systems
article

An Automatic Calibration System for Impedance Head

Bo Zhong, Chenguang Cai, Xiujuan Feng, Hongbo Hu, Anqi Song
article en

Abstract

In order to solve the problems of low efficiency of manual impedance head calibration, such as heavy workload and complex data processing, an automatic calibration system is introduced in this paper. The system, developed in accordance with the ISO 16063-11 standard, integrates a laser interferometer, a signal excitation unit, and a data acquisition module, and is controlled by LabVIEW software. The system uses the sine approximation method to calibrate the sensitivity of acceleration and force. It supports multi-point measurement and automatically generates numerical and graphical reports. Experiments on Brüel & Kjær 8001 impedance head were carried out and preliminary results show that the system has high accuracy, repeatability and operational efficiency. More verification experiments are needed in the future for routine calibration work.

National Institute of Metrology (CN)
Affordable and clean energy
Openalex Percentile: Top 76%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.