Implementation of a Novel Natural Gas Distribution Screening Approach for High Flow Rate Below Ground Leaks Integrated with Company-Specific Emission Factors for Measurement-Informed Annual Emission Inventories

In this study, a novel screening method was implemented by a local distribution company (LDC) to identify below ground pipeline leaks that have high leak flow rates (≥10 scfh CH4, 3.19 g/min) for the purpose of prioritizing repairs and reducing methane emissions. This decision tree (DT) method correlates methane concentration measurements as a function of defined ground surface conditions to leak flow rate. Established threshold methane surface concentrations at each defined surface condition category is used to identify leaks with high flow rates. Direct leak flow rate measurements at more than 400 leak sites were used to evaluate the method and determine the frequency of correctly classifying leak rate bins. These data were used in conjunction with annual leak inventory data to provide robust company-specific CH4 emission factors (C-SEFs) with 90% confidence intervals (CI) of ∼±20%. State-of-the-art statistical analyses, bootstrap resampling, Monte Carlo, and Bayesian probabilistic analyses were used to estimate the DT errors, calculate the C-SEFs and confidence bounds, and estimate annual system emissions with CIs. These C-SEFs explicitly treat the skewed distributions of high flow rate vs low flow rate leaks: 13.3 scfh CH4 (CI 10.4 to 16.6) for leaks ≥10 scfh CH4 and 1.82 scfh CH4 (CI 1.52 to 2.16) for leaks <10 scfh CH4. Furthermore, these C-SEFs do not depend on classification of pipeline types and avoid issues with assigning a pipeline type for each leak. National methane emission estimates from natural gas distribution systems are outdated and have high uncertainty; however, C-SEFs can solve this problem. For the Southern California Gas Company system, annual leak emissions for 2015, before the method was implemented, were 38.3 Gg CH4/yr, similar to an estimate using EPA emission factors. More importantly, the postimplementation 2023 emission estimate of 8.98 Gg CH4/yr (CI 7.33 to 10.8) was 75% less than estimated for 2015. This emission reduction resulted from aggressive improvement in leak management practices implemented since 2015, including increased leak surveys, reduction of leak inventory, and application of the DT method to prioritize high flow leaks for repair.

Authors

Institutions

Publication Details

Journal
ACS ES&T Air
Published
2025-08-22
DOI
https://doi.org/10.1021/acsestair.5c00026
Primary Topic
Atmospheric and Environmental Gas Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of a Novel Natural Gas Distribution Screening Approach for High Flow Rate Below Ground Leaks Integrated with Company-Specific Emission Factors for Measurement-Informed Annual Emission Inventories

Edward Newton, Brian Lamb, Daniel Ersoy, Erik Rodríguez et al.
ACS ES&T Air
Atmospheric and Environmental Gas Dynamics
article

Implementation of a Novel Natural Gas Distribution Screening Approach for High Flow Rate Below Ground Leaks Integrated with Company-Specific Emission Factors for Measurement-Informed Annual Emission Inventories

Edward Newton, Brian Lamb, Daniel Ersoy, Erik Rodríguez, Jeff Powell
article en

Abstract

In this study, a novel screening method was implemented by a local distribution company (LDC) to identify below ground pipeline leaks that have high leak flow rates (≥10 scfh CH4, 3.19 g/min) for the purpose of prioritizing repairs and reducing methane emissions. This decision tree (DT) method correlates methane concentration measurements as a function of defined ground surface conditions to leak flow rate. Established threshold methane surface concentrations at each defined surface condition category is used to identify leaks with high flow rates. Direct leak flow rate measurements at more than 400 leak sites were used to evaluate the method and determine the frequency of correctly classifying leak rate bins. These data were used in conjunction with annual leak inventory data to provide robust company-specific CH4 emission factors (C-SEFs) with 90% confidence intervals (CI) of ∼±20%. State-of-the-art statistical analyses, bootstrap resampling, Monte Carlo, and Bayesian probabilistic analyses were used to estimate the DT errors, calculate the C-SEFs and confidence bounds, and estimate annual system emissions with CIs. These C-SEFs explicitly treat the skewed distributions of high flow rate vs low flow rate leaks: 13.3 scfh CH4 (CI 10.4 to 16.6) for leaks ≥10 scfh CH4 and 1.82 scfh CH4 (CI 1.52 to 2.16) for leaks <10 scfh CH4. Furthermore, these C-SEFs do not depend on classification of pipeline types and avoid issues with assigning a pipeline type for each leak. National methane emission estimates from natural gas distribution systems are outdated and have high uncertainty; however, C-SEFs can solve this problem. For the Southern California Gas Company system, annual leak emissions for 2015, before the method was implemented, were 38.3 Gg CH4/yr, similar to an estimate using EPA emission factors. More importantly, the postimplementation 2023 emission estimate of 8.98 Gg CH4/yr (CI 7.33 to 10.8) was 75% less than estimated for 2015. This emission reduction resulted from aggressive improvement in leak management practices implemented since 2015, including increased leak surveys, reduction of leak inventory, and application of the DT method to prioritize high flow leaks for repair.

ACS ES&T AirVol. 2(9)
Element Six (United States) (US), Washington State University (US), Edison International (United States) (US)
Openalex Percentile: Top 79%
Atmospheric and Environmental Gas Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.