Retention Comparison of Milled Cobalt Chromium and Polyetheretherketone Secondary Telescopic Crowns in Implant-Retained Mandibular Overdentures: A Randomized Clinical Trial

This study aimed to compare the retention of cobalt-chromium and polyetheretherketone secondary telescopic crowns in implant-retained mandibular overdentures. Twelve patients were selected for the study, each received 2 implants in the canine region bilaterally to retain a mandibular overdenture with milled telescopic crowns. The primary crowns with 2° occlusal taper were fabricated using milled titanium abutments. Later, the patients were randomly divided into 2 groups: the cobalt-chromium group, where the secondary crowns were fabricated from milled cobalt-chromium alloy, and the polyetheretherketone group, where secondary crowns were constructed from milled polyetheretherketone. Retention was evaluated at the relative geometric center at baseline (zero months), 6, 9, and 12 months postprosthetic loading using a force meter gauge. The mean of 5 retention force readings was recorded in Newtons for each patient at follow-up visits, and the data were subject to statistical analysis. At baseline, after 6, 9, and 12 months, the CoCr group showed statistically significantly lower mean retention value than the PEEK group. A statistically significant decrease in retention forces within both groups was observed after 12 months postprosthetic loading. The present study suggested that milled cobalt-chromium and polyetheretherketone secondary telescopic crowns in combination with titanium primary conical crowns may provide an acceptable treatment option for completely edentulous patients regarding retentive force. The milled polyetheretherketone secondary telescopic crowns may offer higher retentive force compared to milled cobalt-chromium ones in clinical performance. To prefer one of these materials over the other needs more extensive research.

Authors

Institutions

Publication Details

Journal
Journal of Oral Implantology
Published
2025-08-22
DOI
https://doi.org/10.1563/aaid-joi-d-24-00230
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retention Comparison of Milled Cobalt Chromium and Polyetheretherketone Secondary Telescopic Crowns in Implant-Retained Mandibular Overdentures: A Randomized Clinical Trial

Emad Agamy, Ayman Khalifa, Iman Adel El Asfahani, Doaa Tawfik
Journal of Oral Implantology
Dental Implant Techniques and Outcomes
article

Retention Comparison of Milled Cobalt Chromium and Polyetheretherketone Secondary Telescopic Crowns in Implant-Retained Mandibular Overdentures: A Randomized Clinical Trial

Emad Agamy, Ayman Khalifa, Iman Adel El Asfahani, Doaa Tawfik
article en

Abstract

This study aimed to compare the retention of cobalt-chromium and polyetheretherketone secondary telescopic crowns in implant-retained mandibular overdentures. Twelve patients were selected for the study, each received 2 implants in the canine region bilaterally to retain a mandibular overdenture with milled telescopic crowns. The primary crowns with 2° occlusal taper were fabricated using milled titanium abutments. Later, the patients were randomly divided into 2 groups: the cobalt-chromium group, where the secondary crowns were fabricated from milled cobalt-chromium alloy, and the polyetheretherketone group, where secondary crowns were constructed from milled polyetheretherketone. Retention was evaluated at the relative geometric center at baseline (zero months), 6, 9, and 12 months postprosthetic loading using a force meter gauge. The mean of 5 retention force readings was recorded in Newtons for each patient at follow-up visits, and the data were subject to statistical analysis. At baseline, after 6, 9, and 12 months, the CoCr group showed statistically significantly lower mean retention value than the PEEK group. A statistically significant decrease in retention forces within both groups was observed after 12 months postprosthetic loading. The present study suggested that milled cobalt-chromium and polyetheretherketone secondary telescopic crowns in combination with titanium primary conical crowns may provide an acceptable treatment option for completely edentulous patients regarding retentive force. The milled polyetheretherketone secondary telescopic crowns may offer higher retentive force compared to milled cobalt-chromium ones in clinical performance. To prefer one of these materials over the other needs more extensive research.

Journal of Oral ImplantologyVol. 52(1)
AlAlamein International University (EG), Menoufia University (EG), University of Kordofan (SD), Delta University for Science and Technology (EG), Minia University (EG)
Openalex Percentile: Top 69%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.