Coupling and synchronisation effects on local lock-in of two thermoacoustic oscillators in a stochastic environment
Flame–flame interactions in continuous combustion systems can induce a range of nonlinear dynamical behaviours, particularly in the thermoacoustic context. This study examines the mutual coupling and synchronisation dynamics of two thermoacoustic oscillators in a model gas-turbine combustor operating within a stochastic environment and subjected to external sinusoidal forcing. Experimental observations from two flames in an annular combustor reveal the emergence of dissimilar limit cycles, indicating localised lock-in of thermoacoustic oscillators. To interpret these dynamics, we introduce a coupled stochastic oscillator model with sinusoidal forcing terms, which highlights the critical role of individual synchronisation in enabling local lock-in. Furthermore, through stochastic system identification using this phenomenological low-order model, we mathematically demonstrate that a transition towards self-sustained oscillations can be driven solely by enhanced mutual coupling under external forcing. This combined experimental and modelling effort offers a novel framework for characterising complex coupled flame dynamics in practical combustion systems.
Authors
- Minwoo Lee (ORCID: https://orcid.org/0000-0002-1025-0260)
Institutions
- Hanbat National University (KR)
Publication Details
- Journal
- Journal of Fluid Mechanics
- Published
- 2025-08-22
- DOI
- https://doi.org/10.1017/jfm.2025.10489
- Primary Topic
- Nonlinear Dynamics and Pattern Formation
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Korea Institute of Energy Technology Evaluation and Planning