ASSESSMENT OF SCATTERED X-RAYS TO THE THYROID GLAND OF RADIATION WORKERS IN COMPUTED TOMOGRAPHY (CT) ROOM

Computed tomography (CT) scan is widely used as a rapid and decisive diagnostic method. During CT examinations part of the radiation is scattered from the device. In normal practice, only patient will be allowed to presence inside CT room during examination. However, in some cases medical staff must remain in the CT room. This work aims to study the amount of scattering radiation during CT examinations at Al-Zahraa Hospital, Diyala, Iraq and assess the radiation impact on the thyroid gland hormones for radiation workers to evaluate the severity of the radiation exposure. All data were collected during the month of May to June, 2022. The results showed that the highest amount of scattered radiation was 18.55 mSv in front of the CT gantry head and the lowest scattered radiation was found at both sides of the CT scan device with values of 0.28 mSv and 0.27 mSv. The study also evaluated the impact of scattering radiation on the thyroid gland by testing the triiodothyronine and thyroxine hormones, together with the stimulation hormone in blood from 50 respondents of different gender, age and working time in the CT examination room. The test results showed that the probability of developing thyroid gland disorder increases for radiation workers in comparison to non-radiation workers. These effects were more severe for radiation workers with longer duration of work inside the ionizing radiation units. Thus, exposure to ionizing radiation increases the risk of developing a thyroid gland disorder for workers in CT scan unit.

Authors

Institutions

Publication Details

Journal
Jurnal Teknologi
Published
2025-08-22
DOI
https://doi.org/10.11113/jurnalteknologi.v87.23101
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ASSESSMENT OF SCATTERED X-RAYS TO THE THYROID GLAND OF RADIATION WORKERS IN COMPUTED TOMOGRAPHY (CT) ROOM

F. H. Suhailin, S. Hashim, Waseem Raad Yousifa
Jurnal Teknologi
Radiation Dose and Imaging
article

ASSESSMENT OF SCATTERED X-RAYS TO THE THYROID GLAND OF RADIATION WORKERS IN COMPUTED TOMOGRAPHY (CT) ROOM

F. H. Suhailin, S. Hashim, Waseem Raad Yousifa
article en

Abstract

Computed tomography (CT) scan is widely used as a rapid and decisive diagnostic method. During CT examinations part of the radiation is scattered from the device. In normal practice, only patient will be allowed to presence inside CT room during examination. However, in some cases medical staff must remain in the CT room. This work aims to study the amount of scattering radiation during CT examinations at Al-Zahraa Hospital, Diyala, Iraq and assess the radiation impact on the thyroid gland hormones for radiation workers to evaluate the severity of the radiation exposure. All data were collected during the month of May to June, 2022. The results showed that the highest amount of scattered radiation was 18.55 mSv in front of the CT gantry head and the lowest scattered radiation was found at both sides of the CT scan device with values of 0.28 mSv and 0.27 mSv. The study also evaluated the impact of scattering radiation on the thyroid gland by testing the triiodothyronine and thyroxine hormones, together with the stimulation hormone in blood from 50 respondents of different gender, age and working time in the CT examination room. The test results showed that the probability of developing thyroid gland disorder increases for radiation workers in comparison to non-radiation workers. These effects were more severe for radiation workers with longer duration of work inside the ionizing radiation units. Thus, exposure to ionizing radiation increases the risk of developing a thyroid gland disorder for workers in CT scan unit.

Jurnal TeknologiVol. 87(5)
University of Technology Malaysia (MY)
Universiti Teknologi Malaysia
Openalex Percentile: Top 69%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ASSESSMENT OF SCATTERED X-RAYS TO THE THYROID GLAND OF RADIATION WORKERS IN COMPUTED TOMOGRAPHY (CT) ROOM — F. H. Suhailin, S. Hashim, et al. · Jurnal Teknologi (2025) | TGRS Research Map | TGRS