Investigation of Different Miniscrew-Supported Mesialization Protocols with Finite Element Analysis

Background: To examine the force and stress distributions caused by two different mesialization methods in dentoalveolar structures in cases of congenital bilateral maxillary lateral incisor agenesis (MLIA) with finite element analysis (FEA). Materials and Methods: Two different models were created using FEA. In both models, miniscrews were placed in the palatal region. In the first model, 450 g of force was applied to the miniscrews over the transpalatal arch with the aid of elastic chain. In the second model, the central teeth and miniscrews were connected by using a minimum anchorage unit and 450 g of force was applied to all teeth with the aid of elastic chain over the archwire. For both models, von Mises stress, maximum and minimum principal stresses, and displacement values were recorded. Results: In the first model, the maximum Von Mises stress was observed in the cervix of the miniscrews due to the direct application of the force to the miniscrews. In the second model, the stress was not as intense as in the first model since the force was not applied directly. The greatest displacement was observed in the maxillary first molars in the first model and in the canines in the second model. Compressive and tensile stresses were observed in the maxillary anterior teeth in the second model due to the effect of the elastic chain, while the tensile stress in the maxillary anterior teeth in the first model was almost zero. The amount of transverse and sagittal displacement in the maxillary teeth was higher in the second model compared to the first model. Conclusion: The maximum stress was in the miniscrews in the first model and in the maxillary anterior teeth in the second model. The greatest displacement was observed in the first molars in the first model and in the canines in the second model. Key words: Finite element analysis, congenital maxillary lateral incisor agenesis, mesialization, miniscrew

Authors

Institutions

Publication Details

Journal
Selcuk Dental Journal
Published
2025-08-22
DOI
https://doi.org/10.15311/selcukdentj.1522384
Primary Topic
dental development and anomalies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Different Miniscrew-Supported Mesialization Protocols with Finite Element Analysis

Mehmet Ali Yavan, Gülcan Çetin Taşkıran, Nihal HAMAMCI
Selcuk Dental Journal
dental development and anomalies
article

Investigation of Different Miniscrew-Supported Mesialization Protocols with Finite Element Analysis

Mehmet Ali Yavan, Gülcan Çetin Taşkıran, Nihal HAMAMCI
article en

Abstract

Background: To examine the force and stress distributions caused by two different mesialization methods in dentoalveolar structures in cases of congenital bilateral maxillary lateral incisor agenesis (MLIA) with finite element analysis (FEA). Materials and Methods: Two different models were created using FEA. In both models, miniscrews were placed in the palatal region. In the first model, 450 g of force was applied to the miniscrews over the transpalatal arch with the aid of elastic chain. In the second model, the central teeth and miniscrews were connected by using a minimum anchorage unit and 450 g of force was applied to all teeth with the aid of elastic chain over the archwire. For both models, von Mises stress, maximum and minimum principal stresses, and displacement values were recorded. Results: In the first model, the maximum Von Mises stress was observed in the cervix of the miniscrews due to the direct application of the force to the miniscrews. In the second model, the stress was not as intense as in the first model since the force was not applied directly. The greatest displacement was observed in the maxillary first molars in the first model and in the canines in the second model. Compressive and tensile stresses were observed in the maxillary anterior teeth in the second model due to the effect of the elastic chain, while the tensile stress in the maxillary anterior teeth in the first model was almost zero. The amount of transverse and sagittal displacement in the maxillary teeth was higher in the second model compared to the first model. Conclusion: The maximum stress was in the miniscrews in the first model and in the maxillary anterior teeth in the second model. The greatest displacement was observed in the first molars in the first model and in the canines in the second model. Key words: Finite element analysis, congenital maxillary lateral incisor agenesis, mesialization, miniscrew

Selcuk Dental JournalVol. 12(2)
Adıyaman University (TR)
Openalex Percentile: Top 81%
dental development and anomalies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.