Comparison of Early Clinical and Radiographic Outcomes of Complex Primary and Revision Total Hip Arthroplasty Using a Tapered, Fluted, Modular Titanium Stem System

Background/Objectives: Tapered, fluted, modular titanium stems (TFTSs) are widely used in complex femoral reconstructions during total hip arthroplasty (THA), but evidence regarding the clinical performance of specific modular implant designs remains limited. This study aimed to compare the early clinical and radiographic outcomes of complex primary and revision THA using the M-Vizion® modular stem system. Methods: We retrospectively analyzed 109 patients (46 complex primary and 63 revision THA cases) treated with the M-Vizion® cementless modular TFTSs between 2020 and 2023. Clinical outcomes were assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS) and the Forgotten Joint Score (FJS) at 1- and 2-years post-surgery. Radiographic evaluation included stem subsidence, radiolucent lines, heterotopic ossification, and complications. Clinically relevant subsidence was defined as >5 mm. Statistical analysis was performed using ANOVA. Results: The mean follow-up was 33.3 months for complex primary and 31.8 months for revision THA. Both groups demonstrated significant improvement in FJS over time (p < 0.05). In the revision group, HOOS improved significantly from baseline to follow-up (p < 0.001). Mean stem subsidence was 2.1 mm in the complex primary group and 1.8 mm in the revision group; nine patients (8.3%) had subsidence greater than 5 mm. No cases of aseptic loosening or stem fracture were observed. The overall complication rate was low, with dislocations (3.2%) and infections (2.8%) requiring revision. Conclusions: The M-Vizion® TFTS system demonstrated favorable short-term outcomes in both complex primary and revision THA. These findings suggest potential utility in complex femoral reconstruction, although confirmation through longer-term studies is warranted.

Authors

Institutions

Publication Details

Journal
Prosthesis
Published
2025-08-22
DOI
https://doi.org/10.3390/prosthesis7050104
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Early Clinical and Radiographic Outcomes of Complex Primary and Revision Total Hip Arthroplasty Using a Tapered, Fluted, Modular Titanium Stem System

Giorgio Cacciola, Federico De Meo, Pietro Cavaliere, Antongiulio Bruschetta et al.
Prosthesis
Orthopaedic implants and arthroplasty
article

Comparison of Early Clinical and Radiographic Outcomes of Complex Primary and Revision Total Hip Arthroplasty Using a Tapered, Fluted, Modular Titanium Stem System

Giorgio Cacciola, Federico De Meo, Pietro Cavaliere, Antongiulio Bruschetta, Francesco Bosco
article en

Abstract

Background/Objectives: Tapered, fluted, modular titanium stems (TFTSs) are widely used in complex femoral reconstructions during total hip arthroplasty (THA), but evidence regarding the clinical performance of specific modular implant designs remains limited. This study aimed to compare the early clinical and radiographic outcomes of complex primary and revision THA using the M-Vizion® modular stem system. Methods: We retrospectively analyzed 109 patients (46 complex primary and 63 revision THA cases) treated with the M-Vizion® cementless modular TFTSs between 2020 and 2023. Clinical outcomes were assessed using the Hip Disability and Osteoarthritis Outcome Score (HOOS) and the Forgotten Joint Score (FJS) at 1- and 2-years post-surgery. Radiographic evaluation included stem subsidence, radiolucent lines, heterotopic ossification, and complications. Clinically relevant subsidence was defined as >5 mm. Statistical analysis was performed using ANOVA. Results: The mean follow-up was 33.3 months for complex primary and 31.8 months for revision THA. Both groups demonstrated significant improvement in FJS over time (p < 0.05). In the revision group, HOOS improved significantly from baseline to follow-up (p < 0.001). Mean stem subsidence was 2.1 mm in the complex primary group and 1.8 mm in the revision group; nine patients (8.3%) had subsidence greater than 5 mm. No cases of aseptic loosening or stem fracture were observed. The overall complication rate was low, with dislocations (3.2%) and infections (2.8%) requiring revision. Conclusions: The M-Vizion® TFTS system demonstrated favorable short-term outcomes in both complex primary and revision THA. These findings suggest potential utility in complex femoral reconstruction, although confirmation through longer-term studies is warranted.

ProsthesisVol. 7(5)
Ospedale Humanitas Gradenigo (IT), Department of Medical Sciences (BY), Ospedale G.F. Ingrassia (IT), University of Turin (IT), University of Reggio Calabria (IT), University of Palermo (IT)
Openalex Percentile: Top 65%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.