Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%-70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-08-22
DOI
https://doi.org/10.1021/jasms.5c00111
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Jody C. May, JOHN A. JUN. MCLEAN, Robert L. G. Gottschalk, Hawkins S. Shepard
1 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
0.76
article

Active Humidity Control Chamber for Desorption Electrospray Ionization-Mass Spectrometry Imaging Applications

Jody C. May, JOHN A. JUN. MCLEAN, Robert L. G. Gottschalk, Hawkins S. Shepard
article en
1 citations

Abstract

Ambient ionization techniques enable mass spectrometry (MS) to expand into broader experimental contexts, although it is increasingly clear that results are influenced by the environmental conditions at the site of sampling. Desorption electrospray ionization (DESI), in particular, is affected by variations in relative humidity (RH) levels. Here we describe the design, development, and construction of an environmental control chassis that can actively modulate RH within ± 3% of user-defined set points across a broad humidity range (15%-70% RH). Preliminary characterization demonstrated differential analyte responses across a range of set points, with observed enhancement of leucine-enkephalin, sulfadimethoxine (negative mode), and maltose (positive mode) in response to increased humidity. The measurable differences in analyte signals across discrete humidity set points underscore the importance of environmental control in ambient ionization strategies. The humidity control system outlined here can be translated to other DESI platforms, with construction information provided herein.

Journal of the American Society for Mass SpectrometryVol. 36(9)
Vanderbilt University (US), Virginia Innovation Partnership Corporation (US)
Biological and Environmental Research
Affordable and clean energy
Openalex Percentile: Top 27%
Mass Spectrometry Techniques and Applications
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.