Heat Transfer Analysis of the Evaporator in Boiler Unit 2, Nagan Raya Steam Power Plant

In Indonesia, most power generation facilities employ steam-based systems, including PT PLN Nusantara Power UPK Nagan Raya. To ensure continuous operation, steam power plants must function without operational disruptions, as unplanned shutdowns not only compromise electricity supply but also shorten the service life of associated components. The evaporator, a heat exchanger in the steam boiler, facilitates the phase transition of feedwater from liquid to steam. This research evaluates heat transfer in the evaporator, specifically quantifying the heat transfer rate and assessing the proportion of heat absorbed relative to the thermal energy produced from coal combustion. Measurements were taken under three loading conditions: minimum, medium, and maximum. The maximum heat transfer rate, 184.841 kW, was observed under maximum load, while the lowest, 100.779 kW, occurred under minimum load. Similarly, the highest absorption ratio, 55.49%, was achieved under maximum load, and the lowest, 53.15%, under minimum load. The findings indicate that increased load conditions correspond to higher heat transfer demands, highlighting the influence of loading on both evaporator performance and fuel utilization efficiency.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Science
Published
2024-12-30
DOI
https://doi.org/10.56347/jes.v3i2.266
Primary Topic
Advanced Control Systems Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Transfer Analysis of the Evaporator in Boiler Unit 2, Nagan Raya Steam Power Plant

Ahmad Syuhada, Syahrul Ramadhan, Sarwo EdhyS
Journal of Engineering and Science
Advanced Control Systems Design
article

Heat Transfer Analysis of the Evaporator in Boiler Unit 2, Nagan Raya Steam Power Plant

Ahmad Syuhada, Syahrul Ramadhan, Sarwo EdhyS
article en

Abstract

In Indonesia, most power generation facilities employ steam-based systems, including PT PLN Nusantara Power UPK Nagan Raya. To ensure continuous operation, steam power plants must function without operational disruptions, as unplanned shutdowns not only compromise electricity supply but also shorten the service life of associated components. The evaporator, a heat exchanger in the steam boiler, facilitates the phase transition of feedwater from liquid to steam. This research evaluates heat transfer in the evaporator, specifically quantifying the heat transfer rate and assessing the proportion of heat absorbed relative to the thermal energy produced from coal combustion. Measurements were taken under three loading conditions: minimum, medium, and maximum. The maximum heat transfer rate, 184.841 kW, was observed under maximum load, while the lowest, 100.779 kW, occurred under minimum load. Similarly, the highest absorption ratio, 55.49%, was achieved under maximum load, and the lowest, 53.15%, under minimum load. The findings indicate that increased load conditions correspond to higher heat transfer demands, highlighting the influence of loading on both evaporator performance and fuel utilization efficiency.

Journal of Engineering and ScienceVol. 3(2)
Universitas Syiah Kuala (ID)
Openalex Percentile: Top 61%
Advanced Control Systems Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.