Fault Zone Control on Rapid Groundwater Flow in Cretaceous Carbonates of the Hidden Valley Fault Zone, Texas

Abstract Understanding geological controls on subsurface fluid flow is critical for groundwater resource management and aquifer protection and is particularly challenging in faulted carbonate aquifers due to dissolution and conduit development. We conducted an integrated hydrologic study of the Hidden Valley fault zone in mechanically layered Glen Rose Formation (Trinity Aquifer) exposed in the Canyon Lake gorge in central Texas. Initial hydrologic assessment included geochemistry of water from springs, water wells, and adjacent Canyon Lake, and water temperature, conductivity, and flow monitoring. Geochemistry results indicate spring sourcing from Canyon Lake rather than the Trinity Aquifer. Water temperature and conductivity monitoring indicated complex water movement in the fault zone including spring discharge, surface flow, water infiltration (recharge) along the fault zone, and subsurface flow via secondary porosity (e.g. faults, fractures, vugs). We conducted tracer tests with three distinct dyes (Uranine, Eosin, Phloxine B) at three locations in the fault zone and monitored water at (i) down-gradient springs within the fault zone, (ii) wells in the hanging wall and footwall of the Hidden Valley fault zone, and (iii) the Guadalupe River upstream and downstream of confluence with the gorge outflow. One or more dyes were detected at all down-gradient spring, seep, and stream monitoring sites, but none were detected at monitored water wells or upstream river sites. Uranine injected into a recharge feature (sink) along the fault core travelled laterally underground along the fault zone up to 1993 m/d. Eosin injected in the footwall travelled across the footwall fault damage zone (approximately perpendicular to the fault) at 987 m/d and parallel to the fault at up to 2596 m/d. Fault zone deformation features, including normal faults, extension fractures, and associated dissolution, produced strongly anisotropic hydraulic conductivity that is >7 times larger parallel to the fault compared with perpendicular to the fault.

Authors

Institutions

Publication Details

Journal
Lithosphere
Published
2025-08-22
DOI
https://doi.org/10.2113/2024/lithosphere_2024_178
Citations
1
Primary Topic
Groundwater flow and contamination studies
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Zone Control on Rapid Groundwater Flow in Cretaceous Carbonates of the Hidden Valley Fault Zone, Texas

Adam J. Cawood, David A. Ferrill, F. Paul Bertetti, Gary R. Walter et al.
1 citations
Lithosphere
Groundwater flow and contamination studies
0.80
article

Fault Zone Control on Rapid Groundwater Flow in Cretaceous Carbonates of the Hidden Valley Fault Zone, Texas

Adam J. Cawood, David A. Ferrill, F. Paul Bertetti, Gary R. Walter, Ronald N. McGinnis, Kevin J. Smart, Steven B. Johnson
article en
1 citations

Abstract

Abstract Understanding geological controls on subsurface fluid flow is critical for groundwater resource management and aquifer protection and is particularly challenging in faulted carbonate aquifers due to dissolution and conduit development. We conducted an integrated hydrologic study of the Hidden Valley fault zone in mechanically layered Glen Rose Formation (Trinity Aquifer) exposed in the Canyon Lake gorge in central Texas. Initial hydrologic assessment included geochemistry of water from springs, water wells, and adjacent Canyon Lake, and water temperature, conductivity, and flow monitoring. Geochemistry results indicate spring sourcing from Canyon Lake rather than the Trinity Aquifer. Water temperature and conductivity monitoring indicated complex water movement in the fault zone including spring discharge, surface flow, water infiltration (recharge) along the fault zone, and subsurface flow via secondary porosity (e.g. faults, fractures, vugs). We conducted tracer tests with three distinct dyes (Uranine, Eosin, Phloxine B) at three locations in the fault zone and monitored water at (i) down-gradient springs within the fault zone, (ii) wells in the hanging wall and footwall of the Hidden Valley fault zone, and (iii) the Guadalupe River upstream and downstream of confluence with the gorge outflow. One or more dyes were detected at all down-gradient spring, seep, and stream monitoring sites, but none were detected at monitored water wells or upstream river sites. Uranine injected into a recharge feature (sink) along the fault core travelled laterally underground along the fault zone up to 1993 m/d. Eosin injected in the footwall travelled across the footwall fault damage zone (approximately perpendicular to the fault) at 987 m/d and parallel to the fault at up to 2596 m/d. Fault zone deformation features, including normal faults, extension fractures, and associated dissolution, produced strongly anisotropic hydraulic conductivity that is >7 times larger parallel to the fault compared with perpendicular to the fault.

LithosphereVol. 2024(Special 15)
Southwest Research Institute (US), St. Edward's University (US)
Openalex Percentile: Top 26%
Groundwater flow and contamination studies
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.