Three‐Dimensional Efficient Myelin‐Weighted Imaging Utilizing Direct Visualization of Short Transverse Relaxation Time Component (<scp>ViSTa</scp>)

Measuring myelin concentration in the brain has important implications in basic science and clinical practice. In MRI, myelin water imaging (MWI) has been suggested as a surrogate biomarker that provides high sensitivity and specificity for myelin. However, multi-exponential fitting is ill-conditioned, and it is sensitive to noise and artifacts, particularly in vivo. To overcome the ill-conditioned fitting problem, the two-dimensional ViSTa myelin-weighted imaging technique was proposed, and it provides a substantially improved myelin-weighted image. However, it is based on a two-dimensional single-slice acquisition scheme, and it is a limitation. In this study, a whole brain-covered 3D ViSTa sequence, based on a 3D segmented echo planar imaging (EPI) sequence with a pair of slice selective inversion RF pulses, was proposed. To investigate the 3D ViSTa myelin weighted image, the distribution of myelin content in the white matter of the brain was measured using both conventional MWI and ViSTa MWI. The proposed 3D ViSTa method achieves a whole brain-covered (FOV = 240 × 240 × 128 mm<sup>3</sup>) myelin water-weighted image in less than 8 min (1.5 × 1.5 × 4 mm<sup>3</sup>) and does not require heavy post-processing. Pseudo-quantification (apparent MWF) can be provided by normalizing the ViSTa image with a PD-weighted image. The voxel-wise correlation between the conventional MWI and the 3D ViSTa yielded a mean correlation coefficient of 0.74 ± 0.03 (mean ± standard deviation of the five subjects), demonstrating a high spatial similarity in myelin-weighted contrast between the two maps. The proposed 3D ViSTa with pseudo-quantification may be useful in clinical applications when absolute quantification is not necessary.

Authors

Institutions

Publication Details

Journal
Human Brain Mapping
Published
2025-08-15
DOI
https://doi.org/10.1002/hbm.70307
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three‐Dimensional Efficient Myelin‐Weighted Imaging Utilizing Direct Visualization of Short Transverse Relaxation Time Component (ViSTa)

Se‐Hong Oh, Jong-Ho Lee, Gawon Lee
1 citations
Human Brain Mapping
Advanced MRI Techniques and Applications
1.36
article

Three‐Dimensional Efficient Myelin‐Weighted Imaging Utilizing Direct Visualization of Short Transverse Relaxation Time Component (ViSTa)

Se‐Hong Oh, Jong-Ho Lee, Gawon Lee
article en
1 citations

Abstract

Measuring myelin concentration in the brain has important implications in basic science and clinical practice. In MRI, myelin water imaging (MWI) has been suggested as a surrogate biomarker that provides high sensitivity and specificity for myelin. However, multi-exponential fitting is ill-conditioned, and it is sensitive to noise and artifacts, particularly in vivo. To overcome the ill-conditioned fitting problem, the two-dimensional ViSTa myelin-weighted imaging technique was proposed, and it provides a substantially improved myelin-weighted image. However, it is based on a two-dimensional single-slice acquisition scheme, and it is a limitation. In this study, a whole brain-covered 3D ViSTa sequence, based on a 3D segmented echo planar imaging (EPI) sequence with a pair of slice selective inversion RF pulses, was proposed. To investigate the 3D ViSTa myelin weighted image, the distribution of myelin content in the white matter of the brain was measured using both conventional MWI and ViSTa MWI. The proposed 3D ViSTa method achieves a whole brain-covered (FOV = 240 × 240 × 128 mm<sup>3</sup>) myelin water-weighted image in less than 8 min (1.5 × 1.5 × 4 mm<sup>3</sup>) and does not require heavy post-processing. Pseudo-quantification (apparent MWF) can be provided by normalizing the ViSTa image with a PD-weighted image. The voxel-wise correlation between the conventional MWI and the 3D ViSTa yielded a mean correlation coefficient of 0.74 ± 0.03 (mean ± standard deviation of the five subjects), demonstrating a high spatial similarity in myelin-weighted contrast between the two maps. The proposed 3D ViSTa with pseudo-quantification may be useful in clinical applications when absolute quantification is not necessary.

Human Brain MappingVol. 46(12)
Seoul National University of Science and Technology (KR), Cleveland Clinic (US), Seoul National University (KR), Hankuk University of Foreign Studies (KR)
National Research Foundation, Hankuk University of Foreign Studies, Seoul National University, Korea Health Industry Development Institute, National Research Foundation of Korea, Institute for Information and Communications Technology Promotion, Institute of Engineering Research, Seoul National University
Openalex Percentile: Top 17%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.