Diagnostic Accuracy of Dual-Energy CT Parameters for Discrimination of Hypodense Liver Lesions in Patients Affected by Colorectal Cancer

<b>Objective</b>: The aim of this study was to evaluate the diagnostic accuracy of conventional CT values and the dual-energy computed tomography (DECT)-derived effective atomic number (Zeff), fat fraction (FF) and iodine concentration (IC) for the differentiation of hypodense liver lesions in patients with colorectal cancer (CRC). <b>Methods</b>: One hundred and twenty patients (mean age: 65 ± 12 years) affected by CRC who underwent dual-source DECT as part of tumor staging between December 2015 and June 2023 were retrospectively evaluated. Spectral datasets were reconstructed for each patient and regions of interest were applied at the level of hypodense liver lesions to collect CT, Zeff, FF and IC values. To assess diagnostic accuracy, receiver operating characteristic (ROC) curves were constructed to evaluate the area under the curve (AUC), sensitivity, and specificity using biopsy or MRI (in cases when biopsy was not indicated or feasible) as a reference standard. The Youden index was used to identify optimal cut-off values for potential clinical applications. <b>Results</b>: A total of 223 lesions (147 metastases and 76 cysts) were evaluated. CT, FF and IC values differed significantly between metastases and cysts (<i>p</i> < 0.0001), showing high diagnostic accuracy. FF showed significantly higher diagnostic accuracy compared to all other parameters (all <i>p</i> ≤ 0.0074), with an AUC value of 0.97 (95% CI: 0.94-0.99). For a cut-off > 15.9, the sensitivity reached 91.8% (95% CI: 86.2-95.7) and the specificity reached 98.7% (95% CI: 92.9-100). Zeff numbers did not differ considerably (<i>p</i> = 0.781) between the two entities and demonstrated a lower AUC (0.511; 95% CI: 0.44-0.58). <b>Conclusions</b>: FF measurements proved to have high diagnostic accuracy compared to CT values, IC, and Zeff in the evaluation of hypodense liver lesions in patients suffering from colorectal carcinoma.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-08-22
DOI
https://doi.org/10.3390/jcm14175929
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of Dual-Energy CT Parameters for Discrimination of Hypodense Liver Lesions in Patients Affected by Colorectal Cancer

Scherwin Mahmoudi, Christian Booz, Mirela Dimitrova, Tommaso D’Angelo et al.
Journal of Clinical Medicine
Advanced X-ray and CT Imaging
article

Diagnostic Accuracy of Dual-Energy CT Parameters for Discrimination of Hypodense Liver Lesions in Patients Affected by Colorectal Cancer

Scherwin Mahmoudi, Christian Booz, Mirela Dimitrova, Tommaso D’Angelo, Vitali Koch, Thomas Joseph Vogl, Tilman Steinert, Manuela França, Silvio Mazziotti, Leon David Gruenewald, İbrahim Yel, Ludovica R. M. Lanzafame, Leona S. Alizadeh, Simon S. Martin, Ahmed E. Othman
article en

Abstract

<b>Objective</b>: The aim of this study was to evaluate the diagnostic accuracy of conventional CT values and the dual-energy computed tomography (DECT)-derived effective atomic number (Zeff), fat fraction (FF) and iodine concentration (IC) for the differentiation of hypodense liver lesions in patients with colorectal cancer (CRC). <b>Methods</b>: One hundred and twenty patients (mean age: 65 ± 12 years) affected by CRC who underwent dual-source DECT as part of tumor staging between December 2015 and June 2023 were retrospectively evaluated. Spectral datasets were reconstructed for each patient and regions of interest were applied at the level of hypodense liver lesions to collect CT, Zeff, FF and IC values. To assess diagnostic accuracy, receiver operating characteristic (ROC) curves were constructed to evaluate the area under the curve (AUC), sensitivity, and specificity using biopsy or MRI (in cases when biopsy was not indicated or feasible) as a reference standard. The Youden index was used to identify optimal cut-off values for potential clinical applications. <b>Results</b>: A total of 223 lesions (147 metastases and 76 cysts) were evaluated. CT, FF and IC values differed significantly between metastases and cysts (<i>p</i> < 0.0001), showing high diagnostic accuracy. FF showed significantly higher diagnostic accuracy compared to all other parameters (all <i>p</i> ≤ 0.0074), with an AUC value of 0.97 (95% CI: 0.94-0.99). For a cut-off > 15.9, the sensitivity reached 91.8% (95% CI: 86.2-95.7) and the specificity reached 98.7% (95% CI: 92.9-100). Zeff numbers did not differ considerably (<i>p</i> = 0.781) between the two entities and demonstrated a lower AUC (0.511; 95% CI: 0.44-0.58). <b>Conclusions</b>: FF measurements proved to have high diagnostic accuracy compared to CT values, IC, and Zeff in the evaluation of hypodense liver lesions in patients suffering from colorectal carcinoma.

Journal of Clinical MedicineVol. 14(17)
University of Messina (IT), Goethe University Frankfurt (DE), Johannes Gutenberg University Mainz (DE), University Hospital Frankfurt (DE), Centro Hospitalar do Porto (PT)
Peace, Justice and strong institutions
Openalex Percentile: Top 79%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.