Comparative Analysis of Multi-Organ Failure Trajectories Following Heart Transplantation and HeartMate 3 Implantation: A 1-Year Postprocedural Follow-Up Study Utilizing the MELD-XI Scale

<b>Background</b>: Multi-organ failure (MOF) is a common complication of advanced heart failure (HF), significantly influencing patient prognosis. This study aimed to assess and compare the impact of orthotopic heart transplantation (HTx) and left ventricular assist device (LVAD) implantation on the severity of MOF, as measured by the model for end-stage liver disease excluding INR (MELD-XI) score. <b>Methods</b>: Data from 1 month before to 1 year after HTx or LVAD implantation were analysed. The MELD-XI score was calculated using average bilirubin and creatinine values. Comparative assessments of MELD-XI scores were performed within the HTx and LVAD groups at various time points pre- and post-procedure. <b>Results</b>: The analysis included 107 HTx patients and 30 LVAD patients. The median MELD-XI score 1 month pre-procedure was 11.7 (9.4-16.7) in all patients. There were no significant differences in MELD-XI scores between the groups at 3-, 6-, and 12-month follow-ups. However, a significant difference was observed 1 month post-procedure [HTx: 14.8 (9.4-17.7) vs. LVAD: 11.2 (7.3-14.9), <i>p</i> = 0.02]. In the LVAD group, a significant decrease in MELD-XI score was noted for 3 months post-procedure compared to 1 month pre-procedure (<i>p</i> < 0.001), whereas at 6- and 12-month follow-ups the score did not differ from pre-procedural scores. In the HTx group, significant decreases in MELD-XI scores were observed from 3 months, 6 months, and 1 year post-procedure compared to 1 month pre-procedure (<i>p</i> < 0.002). <b>Conclusions</b>: The MELD-XI scale reveals different MOF trajectories between HTx and LVAD recipients. Both interventions lead to early improvements in liver and kidney function, with sustained benefits in HTx patients, highlighting the distinct impacts on organ function.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-08-22
DOI
https://doi.org/10.3390/jcm14175933
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Multi-Organ Failure Trajectories Following Heart Transplantation and HeartMate 3 Implantation: A 1-Year Postprocedural Follow-Up Study Utilizing the MELD-XI Scale

Magdalena Cielecka, Roman Przybylski, Jakub Ptak, Michał Zakliczyńśki et al.
Journal of Clinical Medicine
Mechanical Circulatory Support Devices
article

Comparative Analysis of Multi-Organ Failure Trajectories Following Heart Transplantation and HeartMate 3 Implantation: A 1-Year Postprocedural Follow-Up Study Utilizing the MELD-XI Scale

Magdalena Cielecka, Roman Przybylski, Jakub Ptak, Michał Zakliczyńśki, Małgorzata Makieła, Dominik Krupka, Maciej Bochenek, Mateusz Sokolski, Joanna Gontarczyk, Paulina Makowska, Mateusz Rakowski, Krystyna E. Wisniewski, Maciej Szwajkowski, Mateusz Waloszczyk, Natalia Sitko
article en

Abstract

<b>Background</b>: Multi-organ failure (MOF) is a common complication of advanced heart failure (HF), significantly influencing patient prognosis. This study aimed to assess and compare the impact of orthotopic heart transplantation (HTx) and left ventricular assist device (LVAD) implantation on the severity of MOF, as measured by the model for end-stage liver disease excluding INR (MELD-XI) score. <b>Methods</b>: Data from 1 month before to 1 year after HTx or LVAD implantation were analysed. The MELD-XI score was calculated using average bilirubin and creatinine values. Comparative assessments of MELD-XI scores were performed within the HTx and LVAD groups at various time points pre- and post-procedure. <b>Results</b>: The analysis included 107 HTx patients and 30 LVAD patients. The median MELD-XI score 1 month pre-procedure was 11.7 (9.4-16.7) in all patients. There were no significant differences in MELD-XI scores between the groups at 3-, 6-, and 12-month follow-ups. However, a significant difference was observed 1 month post-procedure [HTx: 14.8 (9.4-17.7) vs. LVAD: 11.2 (7.3-14.9), <i>p</i> = 0.02]. In the LVAD group, a significant decrease in MELD-XI score was noted for 3 months post-procedure compared to 1 month pre-procedure (<i>p</i> < 0.001), whereas at 6- and 12-month follow-ups the score did not differ from pre-procedural scores. In the HTx group, significant decreases in MELD-XI scores were observed from 3 months, 6 months, and 1 year post-procedure compared to 1 month pre-procedure (<i>p</i> < 0.002). <b>Conclusions</b>: The MELD-XI scale reveals different MOF trajectories between HTx and LVAD recipients. Both interventions lead to early improvements in liver and kidney function, with sustained benefits in HTx patients, highlighting the distinct impacts on organ function.

Journal of Clinical MedicineVol. 14(17)
Wroclaw Medical University (PL)
Openalex Percentile: Top 79%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.