Evaluating the Performance of a Wastewater Treatment Plant of a Dairy Facility in Southern Minas Gerais, Brazil

Dairy wastewater is highly polluting and requires treatment before being discharged into receiving surface waters or destined for reuse. This study aimed to evaluate the performance of a wastewater treatment plant (WWTP) at a dairy facility, which includes the following treatment stages: screening, grease trap, and an upflow anaerobic filter (UAF). Monitoring data from a WWTP at a dairy situated in the southern region of Minas Gerais, Brazil, were assessed based on pollutant removal efficiency in accordance with Brazilian environmental regulations. The results showed that the WWTP achieved average removal efficiencies of 96.2% for COD and 97.1% for BOD5. The BOD5/COD ratio of raw and treated wastewater averaged 0.46 and 0.30, respectively, indicating preferential removal of the biodegradable organic fraction. The treated wastewater complied with legal standards for pH, settleable solids, and total suspended solids. However, at least one sample did not meet regulatory limits for discharge into water bodies regarding surfactants and oils & greases. Strong linear correlations (R2~0.8) between COD and BOD5 data were observed for both raw and treated wastewater. While the treated wastewater was not suitable for use in the facility’s wood-fired boiler, it may be reused for agricultural irrigation.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-08-22
DOI
https://doi.org/10.3390/su17177597
Citations
1
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
1.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Performance of a Wastewater Treatment Plant of a Dairy Facility in Southern Minas Gerais, Brazil

Juan Pablo Pereira Lima, André Aguiar
1 citations
Sustainability
Wastewater Treatment and Reuse
1.00
article

Evaluating the Performance of a Wastewater Treatment Plant of a Dairy Facility in Southern Minas Gerais, Brazil

Juan Pablo Pereira Lima, André Aguiar
article en
1 citations

Abstract

Dairy wastewater is highly polluting and requires treatment before being discharged into receiving surface waters or destined for reuse. This study aimed to evaluate the performance of a wastewater treatment plant (WWTP) at a dairy facility, which includes the following treatment stages: screening, grease trap, and an upflow anaerobic filter (UAF). Monitoring data from a WWTP at a dairy situated in the southern region of Minas Gerais, Brazil, were assessed based on pollutant removal efficiency in accordance with Brazilian environmental regulations. The results showed that the WWTP achieved average removal efficiencies of 96.2% for COD and 97.1% for BOD5. The BOD5/COD ratio of raw and treated wastewater averaged 0.46 and 0.30, respectively, indicating preferential removal of the biodegradable organic fraction. The treated wastewater complied with legal standards for pH, settleable solids, and total suspended solids. However, at least one sample did not meet regulatory limits for discharge into water bodies regarding surfactants and oils & greases. Strong linear correlations (R2~0.8) between COD and BOD5 data were observed for both raw and treated wastewater. While the treated wastewater was not suitable for use in the facility’s wood-fired boiler, it may be reused for agricultural irrigation.

SustainabilityVol. 17(17)
Universidade Federal de Itajubá (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de Minas Gerais, Universidade Federal de Itajubá
Openalex Percentile: Top 20%
Wastewater Treatment and Reuse
1.00
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating the Performance of a Wastewater Treatment Plant of a Dairy Facility in Southern Minas Gerais, Brazil — Juan Pablo Pereira Lima, André Aguiar · Sustainability (2025) | TGRS Research Map | TGRS