Optimization and Analysis of Tangential Component Orientations in OPM-MEG Sensor Array

Optically pumped magnetometers (OPMs) have brought a transformative advancement to magnetoencephalography (MEG), enabling flexible, noncryogenic, and wearable neuroimaging systems. In particular, the development of triaxial OPM sensors allows for simultaneous measurement of full magnetic field vectors, including both radial and additional tangential components. Previous studies have shown that incorporating tangential components helps enhance the separation between neural signals and external interference, but their optimal configurations remain unclear. This study systematically investigated the impact of tangential component configurations on array sensitivity and the lead field correlation coefficient (R12) in triaxial OPM-MEG sensor arrays, considering tangential component rotations, relative orientations of sensor and source, source depths, and head model types. Based on the above analysis, we proposed an optimization strategy aimed at minimizing R12, referred to as R12-minimization array optimization (RMAO), to explore the optimal configuration of tangential components. The simulation results showed that the proposed method significantly enhanced sensitivity to cortical sources and effectively suppressed external interference, enabling more accurate source localization. This study highlights the critical role of tangential components in improving system performance and provides theoretical foundation and methodological guidance for the design of triaxial OPM-MEG sensor arrays.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-08-22
DOI
https://doi.org/10.3390/bioengineering12090903
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization and Analysis of Tangential Component Orientations in OPM-MEG Sensor Array

Xiaolin Ning, Fuzhi Cao, Min Xiang, Zhenfeng Gao et al.
Bioengineering
Atomic and Subatomic Physics Research
article

Optimization and Analysis of Tangential Component Orientations in OPM-MEG Sensor Array

Xiaolin Ning, Fuzhi Cao, Min Xiang, Zhenfeng Gao, Wen Li, Chunhui Wang, Wenli Wang, Nan An
article en

Abstract

Optically pumped magnetometers (OPMs) have brought a transformative advancement to magnetoencephalography (MEG), enabling flexible, noncryogenic, and wearable neuroimaging systems. In particular, the development of triaxial OPM sensors allows for simultaneous measurement of full magnetic field vectors, including both radial and additional tangential components. Previous studies have shown that incorporating tangential components helps enhance the separation between neural signals and external interference, but their optimal configurations remain unclear. This study systematically investigated the impact of tangential component configurations on array sensitivity and the lead field correlation coefficient (R12) in triaxial OPM-MEG sensor arrays, considering tangential component rotations, relative orientations of sensor and source, source depths, and head model types. Based on the above analysis, we proposed an optimization strategy aimed at minimizing R12, referred to as R12-minimization array optimization (RMAO), to explore the optimal configuration of tangential components. The simulation results showed that the proposed method significantly enhanced sensitivity to cortical sources and effectively suppressed external interference, enabling more accurate source localization. This study highlights the critical role of tangential components in improving system performance and provides theoretical foundation and methodological guidance for the design of triaxial OPM-MEG sensor arrays.

BioengineeringVol. 12(9)
Hefei University (CN), Beihang University (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Shandong Province, Key Technology Research and Development Program of Shandong
Openalex Percentile: Top 84%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.