Voltage‐Programmed Sequential Fluorescence Encoding (VPSFE) Enables Multiplexed In Situ Proteo‐Imaging with Electric‐Field Turing Patterns

Abstract DNA barcode‐based immunolabeling has revolutionized single‐cell protein profiling. However, conventional multiplexed imaging methods are hindered by laborious probe exchange procedures involving buffer washing‐based probe removal and prolonged hybridization cycles (requiring tens of minutes to 1.5 h per cycle), which limit throughput, specificity, and universality. Here, we introduce an electrophoresis‐based in situ probe removal method that achieves high‐specificity iterative probe imaging without washing steps, utilizing 2‐min low‐voltage electrophoresis for excess probes removal and 3‐min high‐voltage electrophoresis for hybridized probes dissociation. The robustness was validated through 19 rounds of cyclic electrophoresis, 10 rounds of repetitive imaging, and simultaneous processing of 14 probes (µM‐level) across five rounds of multiprobe exchange, demonstrating exceptional specificity and efficiency. Applied to sequential color coding‐based multiplexed imaging, this approach establishes voltage‐programmed sequential fluorescence encoding (VPSFE), enabling multiplexed imaging of epithelial‐mesenchymal transition (EMT)‐related proteins. Furthermore, we developed a VPSFE‐based Turing pattern coding strategy for multiplexed detection that requires only a single multicolor probe hybridization step. Using three voltage conditions and three fluorescence channels, this system generates 27 unique fluorescence Turing patterns to encode 27 distinct targets. This electric‐field Turing pattern coding strategy represents a novel probe exchange‐free approach for rapid, universal, and highly specific multiplexed in situ imaging.

Authors

Institutions

Publication Details

Journal
Angewandte Chemie
Published
2025-08-22
DOI
https://doi.org/10.1002/ange.202511629
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltage‐Programmed Sequential Fluorescence Encoding (VPSFE) Enables Multiplexed In Situ Proteo‐Imaging with Electric‐Field Turing Patterns

Qinxin Song, Jia‐Yi Zheng, Yi Zhao, Likun Zhang et al.
Angewandte Chemie
Advanced biosensing and bioanalysis techniques
article

Voltage‐Programmed Sequential Fluorescence Encoding (VPSFE) Enables Multiplexed In Situ Proteo‐Imaging with Electric‐Field Turing Patterns

Qinxin Song, Jia‐Yi Zheng, Yi Zhao, Likun Zhang, Zhaoxia Deng, Guohua Zhou, Bingjie Zou, Weihua Yin, Yunlong Liu, Chen Wang, Cheng Yao, Haiping Wu, Zhenghan Xiong, Shuo Liang
article en

Abstract

Abstract DNA barcode‐based immunolabeling has revolutionized single‐cell protein profiling. However, conventional multiplexed imaging methods are hindered by laborious probe exchange procedures involving buffer washing‐based probe removal and prolonged hybridization cycles (requiring tens of minutes to 1.5 h per cycle), which limit throughput, specificity, and universality. Here, we introduce an electrophoresis‐based in situ probe removal method that achieves high‐specificity iterative probe imaging without washing steps, utilizing 2‐min low‐voltage electrophoresis for excess probes removal and 3‐min high‐voltage electrophoresis for hybridized probes dissociation. The robustness was validated through 19 rounds of cyclic electrophoresis, 10 rounds of repetitive imaging, and simultaneous processing of 14 probes (µM‐level) across five rounds of multiprobe exchange, demonstrating exceptional specificity and efficiency. Applied to sequential color coding‐based multiplexed imaging, this approach establishes voltage‐programmed sequential fluorescence encoding (VPSFE), enabling multiplexed imaging of epithelial‐mesenchymal transition (EMT)‐related proteins. Furthermore, we developed a VPSFE‐based Turing pattern coding strategy for multiplexed detection that requires only a single multicolor probe hybridization step. Using three voltage conditions and three fluorescence channels, this system generates 27 unique fluorescence Turing patterns to encode 27 distinct targets. This electric‐field Turing pattern coding strategy represents a novel probe exchange‐free approach for rapid, universal, and highly specific multiplexed in situ imaging.

Angewandte Chemie
China Pharmaceutical University (CN), Nanjing University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province
Openalex Percentile: Top 81%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.