Calculation of effective pump dose in X-ray-pump/X-ray-probe experiments

In pump-probe experiments on solid materials performed within ultrafast X-ray science, the energy deposited by an X-ray pump pulse in the sample has a non-uniform spatial distribution. The following X-ray probe pulse then measures a volume-integrated average of contributions from the differently irradiated regions of the sample. Here we propose a scheme to calculate an effective fluence of the pump pulse such that the observable of interest calculated with the effective fluence is very close to the volume-integrated observable. This approach simplifies computational simulations of X-ray irradiated solids, which typically use periodic boundary conditions and assume a uniformly irradiated simulation box. Obtaining a prediction on a volume-integrated observable requires a significant computational effort, as it is necessary to run multiple simulations for the different exposure conditions and then perform their volume integration. The proposed scheme reduces this effort to a single calculation with the effective fluence.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2025-08-14
DOI
https://doi.org/10.1107/s1600577525006939
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calculation of effective pump dose in X-ray-pump/X-ray-probe experiments

В. И. Ткаченко, Ichiro Inoue, Michal Stránský, Konrad Jerzy Kapcia et al.
Journal of Synchrotron Radiation
Advanced X-ray Imaging Techniques
article

Calculation of effective pump dose in X-ray-pump/X-ray-probe experiments

В. И. Ткаченко, Ichiro Inoue, Michal Stránský, Konrad Jerzy Kapcia, Beata Ziaja, P. Heimann, Sebastião Antunes
article en

Abstract

In pump-probe experiments on solid materials performed within ultrafast X-ray science, the energy deposited by an X-ray pump pulse in the sample has a non-uniform spatial distribution. The following X-ray probe pulse then measures a volume-integrated average of contributions from the differently irradiated regions of the sample. Here we propose a scheme to calculate an effective fluence of the pump pulse such that the observable of interest calculated with the effective fluence is very close to the volume-integrated observable. This approach simplifies computational simulations of X-ray irradiated solids, which typically use periodic boundary conditions and assume a uniformly irradiated simulation box. Obtaining a prediction on a volume-integrated observable requires a significant computational effort, as it is necessary to run multiple simulations for the different exposure conditions and then perform their volume integration. The proposed scheme reduces this effort to a single calculation with the effective fluence.

Journal of Synchrotron RadiationVol. 32(5)
Universität Hamburg (DE), Czech Academy of Sciences (CZ), Deutsches Elektronen-Synchrotron DESY (DE), SLAC National Accelerator Laboratory (US), SPring-8 (JP), Institute of Nuclear Physics, Polish Academy of Sciences (PL), FZU ‒ Institute of Physics of the Academy of Sciences of the Czech Republic (CZ), Linac Coherent Light Source (US), Center for Free-Electron Laser Science (DE), Adam Mickiewicz University in Poznań (PL), European X-Ray Free-Electron Laser (DE)
Narodowa Agencja Wymiany Akademickiej
Openalex Percentile: Top 72%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.