Dedicated prostate DOI-TOF-PET based on the ProVision detection concept

<i>Objective.</i>The ProVision scanner is a dedicated prostate positron emission tomography (PET) system with limited angular coverage; it employs a new detector technology that provides high spatial resolution as well as information about depth-of-interaction (DOI) and time-of-flight (TOF). The goal of this work is to develop a flexible image reconstruction framework and study the image performance of the current ProVision scanner.<i>Approach.</i>Experimental datasets, including point-like sources, an image quality phantom, and a pelvic phantom, were acquired using the ProVision scanner to investigate the impact of oblique lines of response introduced via a multi-offset scanning protocol. This approach aims to mitigate data truncation artefacts and further characterise the current imaging performance of the system. For image reconstruction, we applied the list-mode Maximum Likelihood Expectation Maximisation algorithm incorporating TOF information. The system matrix and sensitivity models account for both detector attenuation and position uncertainty.<i>Main results.</i>The scanner provides good spatial resolution on the coronal plane; however, elongations caused by the limited angular coverage distort the reconstructed images. The availability of TOF and DOI information, as well as the addition of a multi-offset scanning protocol, could not fully compensate for these distortions.<i>Significance.</i>The ProVision scanner concept, with innovative detector technology, shows promising outcomes for fast and inexpensive PET without CT. Despite current limitations due to limited angular coverage, which leads to image distortions, ongoing advancements, such as improved timing resolution, regularisation techniques, and artificial intelligence, are expected to significantly reduce these artefacts and enhance image quality.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-08-22
DOI
https://doi.org/10.1088/1361-6560/adfeb3
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dedicated prostate DOI-TOF-PET based on the ProVision detection concept

K. Doroud, Themistoklis Williams, H. P. Vo, M. Rafecas et al.
Physics in Medicine and Biology
Medical Imaging Techniques and Applications
article

Dedicated prostate DOI-TOF-PET based on the ProVision detection concept

K. Doroud, Themistoklis Williams, H. P. Vo, M. Rafecas, Crispin Williams
article en

Abstract

<i>Objective.</i>The ProVision scanner is a dedicated prostate positron emission tomography (PET) system with limited angular coverage; it employs a new detector technology that provides high spatial resolution as well as information about depth-of-interaction (DOI) and time-of-flight (TOF). The goal of this work is to develop a flexible image reconstruction framework and study the image performance of the current ProVision scanner.<i>Approach.</i>Experimental datasets, including point-like sources, an image quality phantom, and a pelvic phantom, were acquired using the ProVision scanner to investigate the impact of oblique lines of response introduced via a multi-offset scanning protocol. This approach aims to mitigate data truncation artefacts and further characterise the current imaging performance of the system. For image reconstruction, we applied the list-mode Maximum Likelihood Expectation Maximisation algorithm incorporating TOF information. The system matrix and sensitivity models account for both detector attenuation and position uncertainty.<i>Main results.</i>The scanner provides good spatial resolution on the coronal plane; however, elongations caused by the limited angular coverage distort the reconstructed images. The availability of TOF and DOI information, as well as the addition of a multi-offset scanning protocol, could not fully compensate for these distortions.<i>Significance.</i>The ProVision scanner concept, with innovative detector technology, shows promising outcomes for fast and inexpensive PET without CT. Despite current limitations due to limited angular coverage, which leads to image distortions, ongoing advancements, such as improved timing resolution, regularisation techniques, and artificial intelligence, are expected to significantly reduce these artefacts and enhance image quality.

Physics in Medicine and BiologyVol. 70(18)
Sciencetech (Canada) (CA), University of Lübeck (DE)
Deutsche Forschungsgemeinschaft, Eurostars
Openalex Percentile: Top 69%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.