A One-Pot RT-LAMP Diagnostic Assay for SARS-CoV-2 from Saliva Samples

Results of efforts to diagnose infections with SARS-CoV-2 using a sampling method that was less invasive than the nasopharyngeal swab led to the rapid adoption of anterior nasal swabs. Saliva was also shown to have potential as a sample matrix and, like anterior nasal swabs, could be obtained noninvasively (e.g., passive drool). However, due to its inherent complexity and heterogeneity across patient populations (e.g., presence of mucins and RNases), saliva was largely disregarded as point-of-care diagnostics were being developed and broadly implemented. For molecular diagnostic approaches (e.g., RT-PCR or RT-LAMP), these matrix effects from saliva could lead to undesirable false positives or false negatives. The opportunity to address these challenges by normalizing the performance of saliva could enable important applications of molecular tests, particularly at the point-of-care. Toward these goals, we developed a one-pot RT-LAMP assay for the colorimetric detection of SARS-CoV-2 from saliva samples. The assay is performed in five steps: (i) a patient collects a passive saliva sample, (ii) the sample is placed on a heat block for 10 min at 95 °C, (iii) the undiluted sample is added to the one-pot RT-LAMP assay, (iv) the RT-LAMP reaction tube is place on a heat block for 40 min at 65 °C, and, (v) immediately postamplification, the reaction tube is inverted to observe the colorimetric output. We demonstrated the clinical performance of our assay using a panel of 127 patient samples. Our assay had an overall accuracy of 98%, with a sensitivity of 88% and a specificity of 100%. These results indicate excellent diagnostic agreement with the gold standard, RT-PCR, and highlight the potential to improve the clinical utility of saliva for point-of-care (e.g., mobile clinics) testing of SARS-CoV-2 and other upper respiratory viruses and emerging pathogens.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2025-08-22
DOI
https://doi.org/10.1021/acsmeasuresciau.5c00063
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A One-Pot RT-LAMP Diagnostic Assay for SARS-CoV-2 from Saliva Samples

Elizabeth Tzavaras, Charles R. Mace, Paul T. Lawrence, Fiorenzo G. Omenetto et al.
ACS Measurement Science Au
Biosensors and Analytical Detection
article

A One-Pot RT-LAMP Diagnostic Assay for SARS-CoV-2 from Saliva Samples

Elizabeth Tzavaras, Charles R. Mace, Paul T. Lawrence, Fiorenzo G. Omenetto, Mabi Singh, Gustavo Mahn Arteaga, Allison J. Tierney, Andrea C. Mora, Athena Papas, Alexandra K. Sogn
article en

Abstract

Results of efforts to diagnose infections with SARS-CoV-2 using a sampling method that was less invasive than the nasopharyngeal swab led to the rapid adoption of anterior nasal swabs. Saliva was also shown to have potential as a sample matrix and, like anterior nasal swabs, could be obtained noninvasively (e.g., passive drool). However, due to its inherent complexity and heterogeneity across patient populations (e.g., presence of mucins and RNases), saliva was largely disregarded as point-of-care diagnostics were being developed and broadly implemented. For molecular diagnostic approaches (e.g., RT-PCR or RT-LAMP), these matrix effects from saliva could lead to undesirable false positives or false negatives. The opportunity to address these challenges by normalizing the performance of saliva could enable important applications of molecular tests, particularly at the point-of-care. Toward these goals, we developed a one-pot RT-LAMP assay for the colorimetric detection of SARS-CoV-2 from saliva samples. The assay is performed in five steps: (i) a patient collects a passive saliva sample, (ii) the sample is placed on a heat block for 10 min at 95 °C, (iii) the undiluted sample is added to the one-pot RT-LAMP assay, (iv) the RT-LAMP reaction tube is place on a heat block for 40 min at 65 °C, and, (v) immediately postamplification, the reaction tube is inverted to observe the colorimetric output. We demonstrated the clinical performance of our assay using a panel of 127 patient samples. Our assay had an overall accuracy of 98%, with a sensitivity of 88% and a specificity of 100%. These results indicate excellent diagnostic agreement with the gold standard, RT-PCR, and highlight the potential to improve the clinical utility of saliva for point-of-care (e.g., mobile clinics) testing of SARS-CoV-2 and other upper respiratory viruses and emerging pathogens.

ACS Measurement Science AuVol. 5(5)
Tufts University (US)
Office of the Vice Provost for Research, Tufts University, National Institute of Biomedical Imaging and Bioengineering
Zero hunger
Openalex Percentile: Top 79%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.