Digitalization of the Modified Physical Performance Test

Abstract Physical medicine and rehabilitation clinicians frequently measure the physical functions of their patients with neuromuscular motor dysfunction, such as those recovering from stroke, surgery, or trauma. The Modified Physical Performance Test (MPPT) is a widely accepted measure of physical function. However, the MPPT requires significant time investment from the clinician overseeing the test. Our objective was to create a digital MPPT (dMPPT) based on wearable technology which can be performed without extensive clinician oversight and validate the dMPPT using a clinician directed analogue MPPT (aMPPT). Wearable sensors were developed to capture movements performed in the MPPT. A time score and balance score were calculated for each task. A preliminary clinical trial with ten patients in the inpatient section of a rehabilitation unit was conducted. Patients performed both the aMPPT version without the sensors and the dMPPT with the sensors. We compared scores of the aMPPT with the dMPPT. The Pearson correlation test demonstrated a high (r = 0.99) and significant (p < 0.001) correlation between the aMPPT and dMPPT. Bland–Altman analysis determined that data from all ten participants were within the range defined by the limits of agreement, indicating a high level of practical agreement between the aMPPT and dMPPT. The dMPPT results were significantly correlated and demonstrated a high level of practical agreement with the aMPPT clinician-directed method. Future larger sample clinical trials to validate the dMPPT for clinical use are recommended. With this validation, the dMPPT would allow for more efficient monitoring of patients' physical performance.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Science in Medical Diagnostics and Therapy
Published
2025-08-16
DOI
https://doi.org/10.1115/1.4069442
Primary Topic
Children's Physical and Motor Development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digitalization of the Modified Physical Performance Test

Gregory R. Roytman, Yeongmi Kim, Steven M. Tommasini, Daniel H. Wiznia et al.
Journal of Engineering and Science in Medical Diagnostics and Therapy
Children's Physical and Motor Development
article

Digitalization of the Modified Physical Performance Test

Gregory R. Roytman, Yeongmi Kim, Steven M. Tommasini, Daniel H. Wiznia, Rummana Aslam, Larry Wilen, Wolfgang Grosek, Necolle Morgado-Vega, Jessica Garza-Rice
article en

Abstract

Abstract Physical medicine and rehabilitation clinicians frequently measure the physical functions of their patients with neuromuscular motor dysfunction, such as those recovering from stroke, surgery, or trauma. The Modified Physical Performance Test (MPPT) is a widely accepted measure of physical function. However, the MPPT requires significant time investment from the clinician overseeing the test. Our objective was to create a digital MPPT (dMPPT) based on wearable technology which can be performed without extensive clinician oversight and validate the dMPPT using a clinician directed analogue MPPT (aMPPT). Wearable sensors were developed to capture movements performed in the MPPT. A time score and balance score were calculated for each task. A preliminary clinical trial with ten patients in the inpatient section of a rehabilitation unit was conducted. Patients performed both the aMPPT version without the sensors and the dMPPT with the sensors. We compared scores of the aMPPT with the dMPPT. The Pearson correlation test demonstrated a high (r = 0.99) and significant (p < 0.001) correlation between the aMPPT and dMPPT. Bland–Altman analysis determined that data from all ten participants were within the range defined by the limits of agreement, indicating a high level of practical agreement between the aMPPT and dMPPT. The dMPPT results were significantly correlated and demonstrated a high level of practical agreement with the aMPPT clinician-directed method. Future larger sample clinical trials to validate the dMPPT for clinical use are recommended. With this validation, the dMPPT would allow for more efficient monitoring of patients' physical performance.

Journal of Engineering and Science in Medical Diagnostics and TherapyVol. 9(3)
Yale New Haven Hospital (US), Innsbruck Medical University (AT), Yale University (US), Management Center Innsbruck (AT)
Openalex Percentile: Top 77%
Children's Physical and Motor Development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.