Rapid Assessment of Taste Indicators in Orange Juice Using a Handheld Near-infrared Scanner in Transflectance Mode

We evaluated the capability of near-infrared (NIR) transflectance spectroscopy coupled with multivariate analysis to develop predictive regression models that quantify taste indicators, i.e., soluble solids, titratable acidity (TA), citric acid, sucrose, glucose, and fructose, in orange juice (sample size = 123). The NIR spectra were collected in transflectance mode using a handheld scanner with a series of reflectors that provide three distinct pathlengths (0.50 mm, 0.80 mm, and 2 mm) across the juice samples. Reference data were collected using automatic titrators for TA, refractometer for Brix, and high-performance liquid chromatography (HPLC) for organic acids and sugars. Orange juice samples represented a diverse genetic pool of Hamlin and Valencia varieties harvested at different maturity stages providing a unique range of concentration for each parameter (Brix, 4.3–12.3%, and TA 0.8–3.5 g citric acid/L). Pattern recognition analysis correlated the spectral data to reference values using partial least square regression. Results showed better performance using 0.50 mm and 0.80 mm pathlengths, R pre ≥ 0.82, root mean square error of prediction (RMSEP) range 0.14–6.87, residual prediction deviation (RPD) range 1.2–8.3, residual error rate (RER) range 2.7–30 compared to the 2 mm pathlength (R pre ≥ 0.72, RMSEP range 0.27–4.47, RPD range 1.2–1.7, RER range 5.2–7.8). We demonstrated that a field deployable NIR scanner can provide reliable prediction using a transflectance approach using algorithms that were synchronized for cloud computing using R programming, providing easy accessibility for analysis. This technology offers orange breeders and growers an affordable, rapid (10 s), and accurate solution for in-field, real-time monitoring of taste indicators in orange juice, which can help expedite critical decision-making processes in the field (harvest timing, process optimization, and aid in breeding research).

Authors

Institutions

Publication Details

Journal
Applied Spectroscopy Practica
Published
2025-08-14
DOI
https://doi.org/10.1177/27551857251356534
Citations
2
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
1.50

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Assessment of Taste Indicators in Orange Juice Using a Handheld Near-infrared Scanner in Transflectance Mode

Luis Rodriguez‐Saona, Christopher Ball, Shreya Madhav Nuguri, Gio Ijpkemeule et al.
2 citations
Applied Spectroscopy Practica
Spectroscopy and Chemometric Analyses
1.50
article

Rapid Assessment of Taste Indicators in Orange Juice Using a Handheld Near-infrared Scanner in Transflectance Mode

Luis Rodriguez‐Saona, Christopher Ball, Shreya Madhav Nuguri, Gio Ijpkemeule, Celeste Matos Gonzalez
article en
2 citations

Abstract

We evaluated the capability of near-infrared (NIR) transflectance spectroscopy coupled with multivariate analysis to develop predictive regression models that quantify taste indicators, i.e., soluble solids, titratable acidity (TA), citric acid, sucrose, glucose, and fructose, in orange juice (sample size = 123). The NIR spectra were collected in transflectance mode using a handheld scanner with a series of reflectors that provide three distinct pathlengths (0.50 mm, 0.80 mm, and 2 mm) across the juice samples. Reference data were collected using automatic titrators for TA, refractometer for Brix, and high-performance liquid chromatography (HPLC) for organic acids and sugars. Orange juice samples represented a diverse genetic pool of Hamlin and Valencia varieties harvested at different maturity stages providing a unique range of concentration for each parameter (Brix, 4.3–12.3%, and TA 0.8–3.5 g citric acid/L). Pattern recognition analysis correlated the spectral data to reference values using partial least square regression. Results showed better performance using 0.50 mm and 0.80 mm pathlengths, R pre ≥ 0.82, root mean square error of prediction (RMSEP) range 0.14–6.87, residual prediction deviation (RPD) range 1.2–8.3, residual error rate (RER) range 2.7–30 compared to the 2 mm pathlength (R pre ≥ 0.72, RMSEP range 0.27–4.47, RPD range 1.2–1.7, RER range 5.2–7.8). We demonstrated that a field deployable NIR scanner can provide reliable prediction using a transflectance approach using algorithms that were synchronized for cloud computing using R programming, providing easy accessibility for analysis. This technology offers orange breeders and growers an affordable, rapid (10 s), and accurate solution for in-field, real-time monitoring of taste indicators in orange juice, which can help expedite critical decision-making processes in the field (harvest timing, process optimization, and aid in breeding research).

Applied Spectroscopy PracticaVol. 3(3)
State College of Florida Manatee-Sarasota (US), The Ohio State University (US)
PepsiCo
Openalex Percentile: Top 17%
Spectroscopy and Chemometric Analyses
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.