Validation of an EGSnrc Monte Carlo Model of a 10 MV Photon Beam for Varian Clinac iX Linac, Including Flattening and Flattening-Free Modes

Modelling of linear accelerators using the Monte Carlo method is critical for precise radiotherapy planning. In addition, detailed and accurate dose estimation to the organ at risk can be assessed and optimized. In this study, EGSnrc Monte Carlo code was utilized to model, tune, and validate a 10 MV photon head model of a Varian Clinac iX linear accelerator for different field sizes, including flattening and flattening-free modes. Gamma analysis was utilized to compare the model with measured data to determine the best parameters for the incident electron on the target. The main results revealed that, for both flattening and flattening-free modes, the incident electron’s optimal energy is 9.5 MeV, with a 0.1 cm circular full width half maximum (FWHM) and a 0.07° angular divergence. The model is suitable for field sizes extending from 1 × 1 to 30 × 30 cm2. The comparison of large field sizes, which includes both 20 × 20 and 30 × 30 cm2, reflects the accuracy of the geometrical model of the flattening filter. Altering the FWHM has a notable effect on the profile, particularly in the penumbral region, although adjusting the angular divergence has little effect. The dose rate for the flattening filter-free beam compared to the flattening filter beam increased by a factor of four. The validated model demonstrates excellent agreement with measured data. Thus, it can provide accurate dose calculations and can be used in future studies to test treatment accuracy and patient safety, especially for advanced radiotherapy techniques.

Authors

Institutions

Publication Details

Journal
Quantum Beam Science
Published
2025-08-14
DOI
https://doi.org/10.3390/qubs9030025
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an EGSnrc Monte Carlo Model of a 10 MV Photon Beam for Varian Clinac iX Linac, Including Flattening and Flattening-Free Modes

Wafa M. Al-Saleh
1 citations
Quantum Beam Science
Advanced Radiotherapy Techniques
1.88
article

Validation of an EGSnrc Monte Carlo Model of a 10 MV Photon Beam for Varian Clinac iX Linac, Including Flattening and Flattening-Free Modes

Wafa M. Al-Saleh
article en
1 citations

Abstract

Modelling of linear accelerators using the Monte Carlo method is critical for precise radiotherapy planning. In addition, detailed and accurate dose estimation to the organ at risk can be assessed and optimized. In this study, EGSnrc Monte Carlo code was utilized to model, tune, and validate a 10 MV photon head model of a Varian Clinac iX linear accelerator for different field sizes, including flattening and flattening-free modes. Gamma analysis was utilized to compare the model with measured data to determine the best parameters for the incident electron on the target. The main results revealed that, for both flattening and flattening-free modes, the incident electron’s optimal energy is 9.5 MeV, with a 0.1 cm circular full width half maximum (FWHM) and a 0.07° angular divergence. The model is suitable for field sizes extending from 1 × 1 to 30 × 30 cm2. The comparison of large field sizes, which includes both 20 × 20 and 30 × 30 cm2, reflects the accuracy of the geometrical model of the flattening filter. Altering the FWHM has a notable effect on the profile, particularly in the penumbral region, although adjusting the angular divergence has little effect. The dose rate for the flattening filter-free beam compared to the flattening filter beam increased by a factor of four. The validated model demonstrates excellent agreement with measured data. Thus, it can provide accurate dose calculations and can be used in future studies to test treatment accuracy and patient safety, especially for advanced radiotherapy techniques.

Quantum Beam ScienceVol. 9(3)
King Saud bin Abdulaziz University for Health Sciences (SA), King Abdullah International Medical Research Center (SA)
King Abdullah International Medical Research Center
Openalex Percentile: Top 13%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of an EGSnrc Monte Carlo Model of a 10 MV Photon Beam for Varian Clinac iX Linac, Including Flattening and Flattening-Free Modes — Wafa M. Al-Saleh · Quantum Beam Science (2025) | TGRS Research Map | TGRS