The Influence of the Type of Metal-on-Metal Hip Endoprosthesis on the Clinical, Biochemical, and Oxidative Balance Status—A Comparison of Resurfacing and Metaphyseal Implants

<b>Introduction:</b> Despite the increasingly rare use of metal-on-metal articulation, in many countries, there is a large group of patients after hip arthroplasty using this method. The operation of the dysfunctional hip joint using metal-on-metal articulation can be performed by resurfacing or total, stemmed arthroplasty. The aim of this study was to compare the metaphyseal and resurfacing methods in metal-on-metal articulation and its impact on clinical status and variability of oxidative stress parameters, as well as the concentration of chromium and cobalt ions in blood. <b>Materials and methods:</b> The first group operated using BHR (Smith & Nephew) and Biomet ReCap-Magnum metal-on-metal hip resurfacing implants. The second group operated using Biomet ReCap-Magnum with a Microplasty metaphyseal stem. Two clinical evaluations were conducted in each patient with the use of SF-12, HHS, and WOMAC-hip examination scale systems. The concentrations of metal ions in blood and their impacts on the antioxidant system were also determined twice using various oxidative stress markers. <b>Results:</b> The study included 61 males. The mean values of the Cr (<i>p</i> = 0.019) and Co (<i>p</i> = 0.009) ion concentrations were higher in patients after resurfacing arthroplasty. A higher intensity of oxidative stress (activities of sulphydryl groups, malondialdehyde, and lipofuscin) was observed in the resurfacing group compared with the metaphyseal group. <b>Conclusions:</b> The resurfacing hip implant in the metal-on-metal articulation, to a greater extent than the metaphyseal one, elevates the concentration of Cr and Co ions in the blood and is associated with oxidative stress and the functioning of the antioxidant system.

Authors

Institutions

Publication Details

Journal
Nanomaterials
Published
2025-08-15
DOI
https://doi.org/10.3390/nano15161258
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of the Type of Metal-on-Metal Hip Endoprosthesis on the Clinical, Biochemical, and Oxidative Balance Status—A Comparison of Resurfacing and Metaphyseal Implants

Aleksander Augustyn, Dominika Rokicka, Krzysztof Strojek, Michał Dobrakowski et al.
Nanomaterials
Orthopaedic implants and arthroplasty
article

The Influence of the Type of Metal-on-Metal Hip Endoprosthesis on the Clinical, Biochemical, and Oxidative Balance Status—A Comparison of Resurfacing and Metaphyseal Implants

Aleksander Augustyn, Dominika Rokicka, Krzysztof Strojek, Michał Dobrakowski, Marta Wróbel, Sławomir Kasperczyk, Bogdan Koczy, Tomasz Stołtny
article en

Abstract

<b>Introduction:</b> Despite the increasingly rare use of metal-on-metal articulation, in many countries, there is a large group of patients after hip arthroplasty using this method. The operation of the dysfunctional hip joint using metal-on-metal articulation can be performed by resurfacing or total, stemmed arthroplasty. The aim of this study was to compare the metaphyseal and resurfacing methods in metal-on-metal articulation and its impact on clinical status and variability of oxidative stress parameters, as well as the concentration of chromium and cobalt ions in blood. <b>Materials and methods:</b> The first group operated using BHR (Smith & Nephew) and Biomet ReCap-Magnum metal-on-metal hip resurfacing implants. The second group operated using Biomet ReCap-Magnum with a Microplasty metaphyseal stem. Two clinical evaluations were conducted in each patient with the use of SF-12, HHS, and WOMAC-hip examination scale systems. The concentrations of metal ions in blood and their impacts on the antioxidant system were also determined twice using various oxidative stress markers. <b>Results:</b> The study included 61 males. The mean values of the Cr (<i>p</i> = 0.019) and Co (<i>p</i> = 0.009) ion concentrations were higher in patients after resurfacing arthroplasty. A higher intensity of oxidative stress (activities of sulphydryl groups, malondialdehyde, and lipofuscin) was observed in the resurfacing group compared with the metaphyseal group. <b>Conclusions:</b> The resurfacing hip implant in the metal-on-metal articulation, to a greater extent than the metaphyseal one, elevates the concentration of Cr and Co ions in the blood and is associated with oxidative stress and the functioning of the antioxidant system.

NanomaterialsVol. 15(16)
Medical University of Silesia (PL), Demetrix (Poland) (PL)
Openalex Percentile: Top 65%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.