Study on a Repair Clamp Device for Leakage Prevention in Defective Pipes

Clamp repair is a primary method for defective pipe rehabilitation, but the application of repair clamps can conversely affect the safety of the defective pipe. This study presents an optimized repair clamp structure for a defective pipe with diameter of 219 mm through finite element analysis and experimental validation, with a consideration of the sealing performance of clamp. The sealing capability is first verified by contact pressure analysis. When the medium pressure increased from 5 MPa to 20 MPa, the sealing contact pressure correspondingly rose from 11.6 MPa to 27.2 MPa, consistently exceeding the medium pressure. A sensitivity analysis of the maximum safe pressure of defective pipe is then conducted, evaluating critical parameters including defect dimensions, clamp installation distance, and applied pressure range. To ensure safe pipe operation, the recommended optimal installation distance is approximately 40 mm. A hydrostatic pressure test is performed for final validation. Results confirmed the clamp’s robust sealing performance, enabling defective pipe to operate normally at 7.5 MPa medium pressure.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-08-15
DOI
https://doi.org/10.3390/app15169019
Citations
1
Primary Topic
Geotechnical Engineering and Underground Structures
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on a Repair Clamp Device for Leakage Prevention in Defective Pipes

Yuebing Li, Jianguo Feng, Yuxuan Song, Wang Hong et al.
1 citations
Applied Sciences
Geotechnical Engineering and Underground Structures
0.95
article

Study on a Repair Clamp Device for Leakage Prevention in Defective Pipes

Yuebing Li, Jianguo Feng, Yuxuan Song, Wang Hong, Ling Xia, Liao Xiao-ling, Xinjie Suo
article en
1 citations

Abstract

Clamp repair is a primary method for defective pipe rehabilitation, but the application of repair clamps can conversely affect the safety of the defective pipe. This study presents an optimized repair clamp structure for a defective pipe with diameter of 219 mm through finite element analysis and experimental validation, with a consideration of the sealing performance of clamp. The sealing capability is first verified by contact pressure analysis. When the medium pressure increased from 5 MPa to 20 MPa, the sealing contact pressure correspondingly rose from 11.6 MPa to 27.2 MPa, consistently exceeding the medium pressure. A sensitivity analysis of the maximum safe pressure of defective pipe is then conducted, evaluating critical parameters including defect dimensions, clamp installation distance, and applied pressure range. To ensure safe pipe operation, the recommended optimal installation distance is approximately 40 mm. A hydrostatic pressure test is performed for final validation. Results confirmed the clamp’s robust sealing performance, enabling defective pipe to operate normally at 7.5 MPa medium pressure.

Applied SciencesVol. 15(16)
Fujian Special Equipment Inspection Institute (CN), Hangzhou Special Equipment Inspection and Research Institute (CN), Zhejiang University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 22%
Geotechnical Engineering and Underground Structures
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on a Repair Clamp Device for Leakage Prevention in Defective Pipes — Yuebing Li, Jianguo Feng, et al. · Applied Sciences (2025) | TGRS Research Map | TGRS