Freehand ventricular catheter placement in ventriculoperitoneal shunt surgery is associated with higher rates of proximal catheter failure compared to image guidance

Ventricular catheter (VC) revision due to proximal catheter failure is a well-known but potentially avoidable complication of ventriculoperitoneal shunting (VPS). Anatomical “freehand” VC placement is still commonplace, despite image guidance availability. We sought to determine the impact of freehand versus image-guided VC placement on accuracy and consequent revision rates. We conducted a retrospective review of all consecutive adult VPS procedures performed at a single hospital during a two-year period. Only frontal shunts and first-time cannulations of a ventricle were included. Accuracy was measured by linear distance from the catheter tip to the Foramen of Monro (Tip to Foramen, TTF) and Kakarla Grade (KG). Sixty patients met inclusion criteria, with a mean age of 54.1 ± 15.9 years. Most VCs were placed with the freehand technique ( n = 40, 66.7 %), with all revisions (100 %) placed using freehand technique. Use of image guidance significantly increased accurate VC placement by TTF (7.6 ± 6.0 mm vs. 16.1 ± 8.2 mm, p < 0.001) and KG (KG1; 85 % vs. 35 %, p = 0.001), without increasing procedure length (74.8 ± 24.1min vs. 82.3 ± 38.7min, p = 0.219). Four shunts (6.67 %) required VC revision, all within 10 days of surgery. VCs requiring revision were placed significantly less accurately (26.8 ± 9.6 mm vs. 12.02 ± 7.46 mm, p < 0.001). VCs with TTF >2 cm had a significantly higher rate of proximal revision (30 % vs. 2.0 %, p = 0.001). Image-guided placement increases accuracy of proximal shunt catheter placement without sacrificing operative efficiency. VC revision is associated with inaccurate placement and highly inaccurate VCs (>2 cm TTF) are more likely to require revision in the immediate post-operative period.

Authors

Institutions

Publication Details

Journal
World Neurosurgery X
Published
2025-08-15
DOI
https://doi.org/10.1016/j.wnsx.2025.100505
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Freehand ventricular catheter placement in ventriculoperitoneal shunt surgery is associated with higher rates of proximal catheter failure compared to image guidance

Hussam Abou‐Al‐Shaar, Nicolás M. Kass, Stephen P. Canton, Arka N. Mallela et al.
World Neurosurgery X
Cerebrospinal fluid and hydrocephalus
article

Freehand ventricular catheter placement in ventriculoperitoneal shunt surgery is associated with higher rates of proximal catheter failure compared to image guidance

Hussam Abou‐Al‐Shaar, Nicolás M. Kass, Stephen P. Canton, Arka N. Mallela, Nikhil Sharma, Shovan Bhatia, Fritz Steuer, Peter Carlos Gerszten, Lucille Cheng, Regan M. Shanahan, Michael Raver, Michael R. Kann, Jeffery Head, Edward G. Andrews, Sydney Scanlon, Amogh J. Vellore
article en

Abstract

Ventricular catheter (VC) revision due to proximal catheter failure is a well-known but potentially avoidable complication of ventriculoperitoneal shunting (VPS). Anatomical “freehand” VC placement is still commonplace, despite image guidance availability. We sought to determine the impact of freehand versus image-guided VC placement on accuracy and consequent revision rates. We conducted a retrospective review of all consecutive adult VPS procedures performed at a single hospital during a two-year period. Only frontal shunts and first-time cannulations of a ventricle were included. Accuracy was measured by linear distance from the catheter tip to the Foramen of Monro (Tip to Foramen, TTF) and Kakarla Grade (KG). Sixty patients met inclusion criteria, with a mean age of 54.1 ± 15.9 years. Most VCs were placed with the freehand technique ( n = 40, 66.7 %), with all revisions (100 %) placed using freehand technique. Use of image guidance significantly increased accurate VC placement by TTF (7.6 ± 6.0 mm vs. 16.1 ± 8.2 mm, p < 0.001) and KG (KG1; 85 % vs. 35 %, p = 0.001), without increasing procedure length (74.8 ± 24.1min vs. 82.3 ± 38.7min, p = 0.219). Four shunts (6.67 %) required VC revision, all within 10 days of surgery. VCs requiring revision were placed significantly less accurately (26.8 ± 9.6 mm vs. 12.02 ± 7.46 mm, p < 0.001). VCs with TTF >2 cm had a significantly higher rate of proximal revision (30 % vs. 2.0 %, p = 0.001). Image-guided placement increases accuracy of proximal shunt catheter placement without sacrificing operative efficiency. VC revision is associated with inaccurate placement and highly inaccurate VCs (>2 cm TTF) are more likely to require revision in the immediate post-operative period.

World Neurosurgery XVol. 28
University of Pittsburgh (US), University of Pittsburgh Medical Center (US), Neurological Surgery (US)
Good health and well-being
Openalex Percentile: Top 77%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.