A Parametric Study of an Indirect Evaporative Cooler Using a Spray Dryer Model

Indirect evaporative coolers (IECs) are becoming a viable alternative to the more energy-intensive traditional HVAC systems for space cooling, especially in arid regions. In this work, a recently developed computational model of an IEC was used to conduct a parametric study. The model employs a spray dryer model to track the flow path and evaporation rate of droplets. The key parameters investigated were the temperature of the droplets, a bypass effect where the amount of exhaust air and water was reduced to as low as 10%, and the length of the heat exchanger. The results suggest that the wet bulb efficiency could be increased from the previously observed 35% to 72.5% if the water temperature is decreased to 16 °C. In order to drastically increase the performance, the heat exchanger length should be increased from 50 cm to 100 cm, which could still end up in a more compact design overall as fewer plates are required. The bypass study resulted in peak performance when 40% of the secondary air flow was used as working air in conjunction with a proportional reduction in water usage. Overall, the computational model has been employed in an attempt to reduce the bulkiness, increase the efficiency and reduce the water consumption of such a system.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-08-14
DOI
https://doi.org/10.3390/en18164345
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Parametric Study of an Indirect Evaporative Cooler Using a Spray Dryer Model

Torsten Berning, Tianbao Gu, Chungen Yin
Energies
Adsorption and Cooling Systems
article

A Parametric Study of an Indirect Evaporative Cooler Using a Spray Dryer Model

Torsten Berning, Tianbao Gu, Chungen Yin
article en

Abstract

Indirect evaporative coolers (IECs) are becoming a viable alternative to the more energy-intensive traditional HVAC systems for space cooling, especially in arid regions. In this work, a recently developed computational model of an IEC was used to conduct a parametric study. The model employs a spray dryer model to track the flow path and evaporation rate of droplets. The key parameters investigated were the temperature of the droplets, a bypass effect where the amount of exhaust air and water was reduced to as low as 10%, and the length of the heat exchanger. The results suggest that the wet bulb efficiency could be increased from the previously observed 35% to 72.5% if the water temperature is decreased to 16 °C. In order to drastically increase the performance, the heat exchanger length should be increased from 50 cm to 100 cm, which could still end up in a more compact design overall as fewer plates are required. The bypass study resulted in peak performance when 40% of the secondary air flow was used as working air in conjunction with a proportional reduction in water usage. Overall, the computational model has been employed in an attempt to reduce the bulkiness, increase the efficiency and reduce the water consumption of such a system.

EnergiesVol. 18(16)
Aalborg University (DK)
Openalex Percentile: Top 78%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.