Influence of automated façades on comfort and energy: A critical review

• Automation can save up to 75 % lighting energy while providing means to enhance IEQ. • Studies show gaps in automation acceptance and occupant satisfaction among occupants. • Different metrics affect the consistent evaluation of automated façade performance. • Integrating energy, IEQ, and occupant interaction can balance comfort and efficiency. • Further research is needed on integrating occupant preferences into automation. In recent years, several studies have assessed the influence of automated façades on energy savings, IEQ, and occupant satisfaction. However, discrepancies exist between the expected advantages of automated façades predicted in research and the actual benefits observed in real-world tests. To assess how automated façade operation enhances building performance, in particular within office building contexts, this study reviews and analyzes current evidence on the influence of automated façades. In this review, 91 studies were identified presenting evidence of their performance. A total of 34 studies investigated performance in laboratory settings, 23 in real office buildings, and 34 in simulations. Only 13 laboratory studies and 17 real office building studies included human participants. Visual and thermal quality were the main indoor environmental domains investigated, with limited exploration of others. Existing studies show large variability in contextual factors (e.g., type of shading and control) or experimental designs (e.g., different benchmark scenarios), hindering the comparison of results. Consistent evidence shows the potential of automated façades for energy savings, particularly in lighting and cooling demands, which outperform manual control systems. Automated controls are more effective in reducing excessive daylight and glare, while evidence of the impact on thermal and air quality remains limited. Regarding occupant satisfaction, evidence is unclear since, in some cases, occupants prefer manually controlled façades and, in others, automated ones. Further research is suggested on human-centered studies in real office buildings to capture occupant behavior and preferences while exploring solutions that dynamically identify and integrate factors affecting occupant interaction with buildings.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-08-15
DOI
https://doi.org/10.1016/j.enbuild.2025.116290
Citations
3
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
3.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of automated façades on comfort and energy: A critical review

Eleonora Brembilla, Ulrich Knaack, Claudio Vásquez Zaldívar, Pedro de la Barra et al.
3 citations
Energy and Buildings
Building Energy and Comfort Optimization
3.02
article

Influence of automated façades on comfort and energy: A critical review

Eleonora Brembilla, Ulrich Knaack, Claudio Vásquez Zaldívar, Pedro de la Barra, Alejandro Prieto, Alessandra Luna-Navarro
article en
3 citations

Abstract

• Automation can save up to 75 % lighting energy while providing means to enhance IEQ. • Studies show gaps in automation acceptance and occupant satisfaction among occupants. • Different metrics affect the consistent evaluation of automated façade performance. • Integrating energy, IEQ, and occupant interaction can balance comfort and efficiency. • Further research is needed on integrating occupant preferences into automation. In recent years, several studies have assessed the influence of automated façades on energy savings, IEQ, and occupant satisfaction. However, discrepancies exist between the expected advantages of automated façades predicted in research and the actual benefits observed in real-world tests. To assess how automated façade operation enhances building performance, in particular within office building contexts, this study reviews and analyzes current evidence on the influence of automated façades. In this review, 91 studies were identified presenting evidence of their performance. A total of 34 studies investigated performance in laboratory settings, 23 in real office buildings, and 34 in simulations. Only 13 laboratory studies and 17 real office building studies included human participants. Visual and thermal quality were the main indoor environmental domains investigated, with limited exploration of others. Existing studies show large variability in contextual factors (e.g., type of shading and control) or experimental designs (e.g., different benchmark scenarios), hindering the comparison of results. Consistent evidence shows the potential of automated façades for energy savings, particularly in lighting and cooling demands, which outperform manual control systems. Automated controls are more effective in reducing excessive daylight and glare, while evidence of the impact on thermal and air quality remains limited. Regarding occupant satisfaction, evidence is unclear since, in some cases, occupants prefer manually controlled façades and, in others, automated ones. Further research is suggested on human-centered studies in real office buildings to capture occupant behavior and preferences while exploring solutions that dynamically identify and integrate factors affecting occupant interaction with buildings.

Energy and BuildingsVol. 347
Universidad Católica del Norte (CL), Universidad Diego Portales (CL), Delft University of Technology (NL)
Openalex Percentile: Top 9%
Building Energy and Comfort Optimization
3.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.