Challenges and Overall Performance of an Industrial Wastewater Treatment Plant: A Case Study of Bu-Ali Industrial Town, Hamadan

The present study aimed to investigate and evaluate the performance of the Bu-Ali Industrial Town wastewater treatment plant (WWTP), Hamadan, Iran. In this study, the physicochemical and microbial characteristics and heavy metal contents of influent and effluent were evaluated. The mean values of total suspended solids (TSS), total dissolved solids (TDS), chemical oxygen demand (COD), dissolved oxygen (DO), biological oxygen demand (BOD5 ), cyanide, total coliform (TC), fecal coliform and pH in influent were 1210 mg/L, 2165.5 mg/L, 2187.5 mg/L, 2.4 mg/L, 967.5 mg/L, 20.8 mg/L, 1.3×1010 (MPN/100 mL), 1.2×109 (MPN/100 mL) and 6.7, respectively. Additionally, the mean values of the mentioned parameters in effluent were 94.5 mg/L, 2370.4 mg/L, 220.7 mg/L, 5.2 mg/L, 113.4 mg/L, 2.0 mg/L, 1.7×106 (MPN/100 mL), 3.5×104 (MPN/100 mL), and 8.7, respectively. The concentrations of metals including V, Cd, Co, Cu, Cr, Hg, Ni, Pb, and Zn at the inlet of the treatment plant were measured to be 3.9, 14.5, 5.6, 77.9, 142.4,<0.3, 104.0, 73.8, and 720.6 ppb and at the treatment plant, the corresponding concentrations were<0.06, 11.8, 2.4, 14.6, 19.1,<0.3, 73.1, 10.8, and 34.5 ppb. Based on the results, the measured values of some parameters, such as BOD5 , COD, coliforms, and cyanide in the effluent, were higher than the standards set by various organizations. Therefore, discharging such effluent into the environment can harm the ecosystem; their high values result from the lack of any pre-treatment units in various industries. Hence, by obliging certain industries to pre-treat their wastewater before discharging it into the combined wastewater collection system, the above-mentioned parameters can be adjusted to some extent. In addition, considering the high microbial load of the effluent, continuous disinfection and improvement of the disinfection unit can play a significant role in reducing the microbial load of the effluent.

Authors

Institutions

Publication Details

Journal
Avicenna Journal of Environmental Health Engineering
Published
2025-06-29
DOI
https://doi.org/10.34172/ajehe.5563
Primary Topic
Water Quality and Pollution Assessment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Challenges and Overall Performance of an Industrial Wastewater Treatment Plant: A Case Study of Bu-Ali Industrial Town, Hamadan

Reza Shokoohi, Hassan Zolghadrnasab, Ghasem Azarian, Ghorban Asgari et al.
Avicenna Journal of Environmental Health Engineering
Water Quality and Pollution Assessment
article

Challenges and Overall Performance of an Industrial Wastewater Treatment Plant: A Case Study of Bu-Ali Industrial Town, Hamadan

Reza Shokoohi, Hassan Zolghadrnasab, Ghasem Azarian, Ghorban Asgari, Mostafa Leili, Madineh Jakipour
article en

Abstract

The present study aimed to investigate and evaluate the performance of the Bu-Ali Industrial Town wastewater treatment plant (WWTP), Hamadan, Iran. In this study, the physicochemical and microbial characteristics and heavy metal contents of influent and effluent were evaluated. The mean values of total suspended solids (TSS), total dissolved solids (TDS), chemical oxygen demand (COD), dissolved oxygen (DO), biological oxygen demand (BOD5 ), cyanide, total coliform (TC), fecal coliform and pH in influent were 1210 mg/L, 2165.5 mg/L, 2187.5 mg/L, 2.4 mg/L, 967.5 mg/L, 20.8 mg/L, 1.3×1010 (MPN/100 mL), 1.2×109 (MPN/100 mL) and 6.7, respectively. Additionally, the mean values of the mentioned parameters in effluent were 94.5 mg/L, 2370.4 mg/L, 220.7 mg/L, 5.2 mg/L, 113.4 mg/L, 2.0 mg/L, 1.7×106 (MPN/100 mL), 3.5×104 (MPN/100 mL), and 8.7, respectively. The concentrations of metals including V, Cd, Co, Cu, Cr, Hg, Ni, Pb, and Zn at the inlet of the treatment plant were measured to be 3.9, 14.5, 5.6, 77.9, 142.4,<0.3, 104.0, 73.8, and 720.6 ppb and at the treatment plant, the corresponding concentrations were<0.06, 11.8, 2.4, 14.6, 19.1,<0.3, 73.1, 10.8, and 34.5 ppb. Based on the results, the measured values of some parameters, such as BOD5 , COD, coliforms, and cyanide in the effluent, were higher than the standards set by various organizations. Therefore, discharging such effluent into the environment can harm the ecosystem; their high values result from the lack of any pre-treatment units in various industries. Hence, by obliging certain industries to pre-treat their wastewater before discharging it into the combined wastewater collection system, the above-mentioned parameters can be adjusted to some extent. In addition, considering the high microbial load of the effluent, continuous disinfection and improvement of the disinfection unit can play a significant role in reducing the microbial load of the effluent.

Avicenna Journal of Environmental Health EngineeringVol. 12(1)
Hamedan University of Medical Sciences (IR)
Hamadan University of Medical Sciences
Openalex Percentile: Top 79%
Water Quality and Pollution Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.