TIME-DEPENDENT VARIABILITY OF D-DIMER LEVEL IN BLOOD SAMPLE OF COVID POSITIVE PATIENT

Background: Coronavirus disease 2019 (COVID-19) has emerged as a global health crisis, causing significant morbidity and mortality. Beyond its respiratory manifestations, it has profound systemic effects, particularly on the cardiovascular system, where it predisposes patients to hypercoagulability and disseminated intravascular coagulation (DIC). D-dimer, a fibrin degradation product, is widely used as a biomarker to assess thrombotic activity and disease progression. Establishing whether storage time influences D-dimer values is essential for ensuring laboratory accuracy and reliability, especially under strained healthcare conditions. Objective: This study aimed to evaluate the effect of short-term storage time on D-dimer levels in samples from COVID-19–positive patients compared with healthy controls. Methods: A case–control study was conducted at Hayatabad Medical Complex, Peshawar, between June and August 2021. A total of 100 participants were enrolled, including 50 confirmed COVID-19–positive patients and 50 healthy controls. Venous blood samples (2 mL) were collected in sodium citrate tubes from the antecubital vein of each participant and analyzed using a Cobas c501 analyzer. Samples were tested immediately (0 hours), after 4 hours, and after 8 hours at room temperature. Patients with comorbidities were excluded. Paired sample t-tests were applied to assess time-related differences in D-dimer values, and Pearson correlation was used to explore associations between time and D-dimer levels. Results: In COVID-19–positive patients, the mean baseline D-dimer level was 3.77 ± 3.71 µg/mL FEU, increasing slightly to 3.81 ± 3.73 at 4 hours and 4.00 ± 3.80 at 8 hours. The corresponding two-tailed p-values were 0.366 and 0.174, both above the 0.05 threshold, indicating no statistically significant variation over time. Controls maintained consistently low D-dimer levels (0.69 ± 0.40 at baseline, 0.68 ± 0.39 at 4 hours, and 0.70 ± 0.39 at 8 hours) with p-values of 0.159. Pearson correlation revealed a weak, clinically negligible association between time and D-dimer levels. Conclusion: D-dimer values in COVID-19–positive samples remained stable over 8 hours of storage at room temperature, confirming that short-term delays in analysis do not compromise test accuracy. This stability enhances the practical utility of D-dimer testing in clinical laboratories, particularly during peak workloads in pandemics.

Authors

Institutions

Publication Details

Journal
Insights-Journal of Health and Rehabilitation
Published
2025-08-18
DOI
https://doi.org/10.71000/4a5jcw37
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TIME-DEPENDENT VARIABILITY OF D-DIMER LEVEL IN BLOOD SAMPLE OF COVID POSITIVE PATIENT

Rizwan Ullah, Ülker Gül, Said Wali, Abdur Rehman et al.
Insights-Journal of Health and Rehabilitation
Renal function and acid-base balance
article

TIME-DEPENDENT VARIABILITY OF D-DIMER LEVEL IN BLOOD SAMPLE OF COVID POSITIVE PATIENT

Rizwan Ullah, Ülker Gül, Said Wali, Abdur Rehman, Emad Ud Din
article en

Abstract

Background: Coronavirus disease 2019 (COVID-19) has emerged as a global health crisis, causing significant morbidity and mortality. Beyond its respiratory manifestations, it has profound systemic effects, particularly on the cardiovascular system, where it predisposes patients to hypercoagulability and disseminated intravascular coagulation (DIC). D-dimer, a fibrin degradation product, is widely used as a biomarker to assess thrombotic activity and disease progression. Establishing whether storage time influences D-dimer values is essential for ensuring laboratory accuracy and reliability, especially under strained healthcare conditions. Objective: This study aimed to evaluate the effect of short-term storage time on D-dimer levels in samples from COVID-19–positive patients compared with healthy controls. Methods: A case–control study was conducted at Hayatabad Medical Complex, Peshawar, between June and August 2021. A total of 100 participants were enrolled, including 50 confirmed COVID-19–positive patients and 50 healthy controls. Venous blood samples (2 mL) were collected in sodium citrate tubes from the antecubital vein of each participant and analyzed using a Cobas c501 analyzer. Samples were tested immediately (0 hours), after 4 hours, and after 8 hours at room temperature. Patients with comorbidities were excluded. Paired sample t-tests were applied to assess time-related differences in D-dimer values, and Pearson correlation was used to explore associations between time and D-dimer levels. Results: In COVID-19–positive patients, the mean baseline D-dimer level was 3.77 ± 3.71 µg/mL FEU, increasing slightly to 3.81 ± 3.73 at 4 hours and 4.00 ± 3.80 at 8 hours. The corresponding two-tailed p-values were 0.366 and 0.174, both above the 0.05 threshold, indicating no statistically significant variation over time. Controls maintained consistently low D-dimer levels (0.69 ± 0.40 at baseline, 0.68 ± 0.39 at 4 hours, and 0.70 ± 0.39 at 8 hours) with p-values of 0.159. Pearson correlation revealed a weak, clinically negligible association between time and D-dimer levels. Conclusion: D-dimer values in COVID-19–positive samples remained stable over 8 hours of storage at room temperature, confirming that short-term delays in analysis do not compromise test accuracy. This stability enhances the practical utility of D-dimer testing in clinical laboratories, particularly during peak workloads in pandemics.

Insights-Journal of Health and RehabilitationVol. 3(4 (Health and Allied))
Khyber Medical University (PK)
Openalex Percentile: Top 76%
Renal function and acid-base balance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.