Pengaruh Variasi Ukuran dan Penempatan Void Plat Lantai terhadap Perilaku dan Kekuatan Gedung Bertingkat

One of the developments in the world of construction is the variety of structural system configuration types to ensure the strength, stability, efficiency, and safety of buildings. An example of a frequently encountered structural configuration variation is the presence of voids or holes in the floor slab of a building. Floor slabs that have voids affect the structural strength. This study aims to analyze the effect of variations in the size and placement of floor slab voids on the behavior and strength of multi-storey building structures. The results of the analysis are expected to be used as a reference in selecting the size and placement of floor slab voids in building planning. The building structure model analyzed is an 8-storey regular building structure with reinforced concrete materials. The height between floors is 4 meters and the total height of the building is 32 meters. The function of the building is an office located in Semarang City. The earthquake-resistant structural system used is the Special Moment Resisting Frame System (SRPMK). The floor plan size is 18x18 meters with a span between columns of 6 meters. The variations used are 6 void models with different sizes and placements. Each structural model is analyzed using ETABS software. The analysis results state that the larger the void size, the smaller the structural period, the smaller the inter-floor shear force value, and the smaller the inter-floor drift value. The recommendation for selecting the most effective size variations and void placement is in a structural model where the void is placed in the middle of the structure with the largest void size being 6x6 meters.

Authors

Publication Details

Journal
Jurnal Talenta Sipil
Published
2025-08-04
DOI
https://doi.org/10.33087/talentasipil.v8i2.970
Primary Topic
Material Properties and Processing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pengaruh Variasi Ukuran dan Penempatan Void Plat Lantai terhadap Perilaku dan Kekuatan Gedung Bertingkat

Pramesta Armanisag Pangestuti, Agustinus Sungsang Nana Patria, Ilham Putra Sholikhin
1 links
Jurnal Talenta Sipil
Material Properties and Processing
article

Pengaruh Variasi Ukuran dan Penempatan Void Plat Lantai terhadap Perilaku dan Kekuatan Gedung Bertingkat

Pramesta Armanisag Pangestuti, Agustinus Sungsang Nana Patria, Ilham Putra Sholikhin
article en

Abstract

One of the developments in the world of construction is the variety of structural system configuration types to ensure the strength, stability, efficiency, and safety of buildings. An example of a frequently encountered structural configuration variation is the presence of voids or holes in the floor slab of a building. Floor slabs that have voids affect the structural strength. This study aims to analyze the effect of variations in the size and placement of floor slab voids on the behavior and strength of multi-storey building structures. The results of the analysis are expected to be used as a reference in selecting the size and placement of floor slab voids in building planning. The building structure model analyzed is an 8-storey regular building structure with reinforced concrete materials. The height between floors is 4 meters and the total height of the building is 32 meters. The function of the building is an office located in Semarang City. The earthquake-resistant structural system used is the Special Moment Resisting Frame System (SRPMK). The floor plan size is 18x18 meters with a span between columns of 6 meters. The variations used are 6 void models with different sizes and placements. Each structural model is analyzed using ETABS software. The analysis results state that the larger the void size, the smaller the structural period, the smaller the inter-floor shear force value, and the smaller the inter-floor drift value. The recommendation for selecting the most effective size variations and void placement is in a structural model where the void is placed in the middle of the structure with the largest void size being 6x6 meters.

Jurnal Talenta SipilVol. 8(2)
Openalex Percentile: Top 76%
Material Properties and Processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pengaruh Variasi Ukuran dan Penempatan Void Plat Lantai terhadap Perilaku dan Kekuatan Gedung Bertingkat — Pramesta Armanisag Pangestuti, Agustinus Sungsang Nana Patria, et al. · Jurnal Talenta Sipil (2025) | TGRS Research Map | TGRS