Analysis of Electronic Transformer Interference Test Based on Gas Switching Insulation Equipment

As an important electrical measurement device in high-voltage power systems, electronic transformers are susceptible to electromagnetic interference from disconnecting switch opening and closing operations, which can lead to circuit failures. In order to assess the maximum level of interference it can withstand, a method of EMI testing of electronic transformers is proposed, and a test platform based on gas-insulated switchgear is constructed. To analyse the mechanism of the electronic transformer interference test, Spearman rank correlation analysis is used to analyse the overvoltage at the primary side and the interference signal at the secondary side during the switching operation, and the results show that there is a linear correlation between the amplitude of the interference voltage pulses at the secondary side port and the breakdown voltage between the breaks on the primary side. The method proposed in this study can provide technical support for the testing, analysis and suppression methods of electromagnetic interference of primary and secondary side fusion equipment in substations.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/iaecst64597.2024.11117836
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Electronic Transformer Interference Test Based on Gas Switching Insulation Equipment

Shoucheng Ji, Shanshan Gao, Zhengxin Gao, Ziang Yue et al.
Advanced Sensor and Control Systems
article

Analysis of Electronic Transformer Interference Test Based on Gas Switching Insulation Equipment

Shoucheng Ji, Shanshan Gao, Zhengxin Gao, Ziang Yue, Bin Xv, Baicheng Xv
article en

Abstract

As an important electrical measurement device in high-voltage power systems, electronic transformers are susceptible to electromagnetic interference from disconnecting switch opening and closing operations, which can lead to circuit failures. In order to assess the maximum level of interference it can withstand, a method of EMI testing of electronic transformers is proposed, and a test platform based on gas-insulated switchgear is constructed. To analyse the mechanism of the electronic transformer interference test, Spearman rank correlation analysis is used to analyse the overvoltage at the primary side and the interference signal at the secondary side during the switching operation, and the results show that there is a linear correlation between the amplitude of the interference voltage pulses at the secondary side port and the breakdown voltage between the breaks on the primary side. The method proposed in this study can provide technical support for the testing, analysis and suppression methods of electromagnetic interference of primary and secondary side fusion equipment in substations.

Gannan Normal University (CN), Shandong Special Equipment Inspection Institute (CN), Shanghai Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 61%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Electronic Transformer Interference Test Based on Gas Switching Insulation Equipment — Shoucheng Ji, Shanshan Gao, et al. · (2024) | TGRS Research Map | TGRS