Research on Countermeasures of Inrush Current in 10kV Distribution Network Line

The number and capacity of distribution transformers on the 10 kV distribution network line are increasing. In the process of voltage recovery after no-load closing or fault removal, the distribution transformer will generate magnetizing inrush current. The magnetizing inrush current generated by multiple distribution transformers is <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$s$</tex> uperimposed on each other, so that the magnetizing inrush current on the line increases. The intelligent switch can not identify and distinguish the magnetizing inrush current and the fault current, which will lead to the misoperation of the overcurrent protection of the intelligent switch and expand the power outage range. In order to ensure that the equipment can work stably when it is put into operation, a composite voltage blocking overcurrent protection is proposed to avoid inrush current measures and avoid the misoperation of relay protection of 10 kV distribution network line switch.

Authors

Institutions

Publication Details

Published
2024-12-06
DOI
https://doi.org/10.1109/iaecst64597.2024.11117213
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Countermeasures of Inrush Current in 10kV Distribution Network Line

Qing Wang, Shulin Liu
Power Systems Fault Detection
article

Research on Countermeasures of Inrush Current in 10kV Distribution Network Line

Qing Wang, Shulin Liu
article en

Abstract

The number and capacity of distribution transformers on the 10 kV distribution network line are increasing. In the process of voltage recovery after no-load closing or fault removal, the distribution transformer will generate magnetizing inrush current. The magnetizing inrush current generated by multiple distribution transformers is <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$s$</tex> uperimposed on each other, so that the magnetizing inrush current on the line increases. The intelligent switch can not identify and distinguish the magnetizing inrush current and the fault current, which will lead to the misoperation of the overcurrent protection of the intelligent switch and expand the power outage range. In order to ensure that the equipment can work stably when it is put into operation, a composite voltage blocking overcurrent protection is proposed to avoid inrush current measures and avoid the misoperation of relay protection of 10 kV distribution network line switch.

Xi'an University of Science and Technology (CN)
Openalex Percentile: Top 61%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.