Contribution of x-ray incident position dependence to energy resolution of Ti/Au transition-edge sensors

Abstract We present the contribution of x-ray incident-position dependence on the absorber to the energy resolution of Ti/Au transition-edge sensors (TESs). The pulse height varies with the position due to insufficient thermal conductivity and geometry of the absorber that degrades the measured energy resolution. We develop a three-dimensional (3D) electro-thermal simulation model and thoroughly study the position dependent contribution to energy resolution (Δ E p ) for two presentative absorber structures: an absorber directly deposited on the center of TES sensor (design A) and an absorber cantilevered on the TES sensor by several stems (design B). For design A with a 30 μm × 40 μm Au absorber Δ E p is found to be 9.4 eV, while it is reduced to 1.35 eV for design B with a 100 μm × 100 μm Au absorber. Although the contribution of position dependence is relatively small, this study facilitates further optimization of the absorber structure to achieve enhanced energy resolution.

Authors

Institutions

Publication Details

Journal
Chinese Physics B
Published
2025-08-15
DOI
https://doi.org/10.1088/1674-1056/adfbd6
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contribution of x-ray incident position dependence to energy resolution of Ti/Au transition-edge sensors

Jiaqiang Zhong, Peizhan Li, Feng Zhu, Yuan Ren et al.
Chinese Physics B
Nuclear Physics and Applications
article

Contribution of x-ray incident position dependence to energy resolution of Ti/Au transition-edge sensors

Jiaqiang Zhong, Peizhan Li, Feng Zhu, Yuan Ren, Xianfeng Zhou, Jing Li, Wen Zhang, Zheng Wang, Wei Miao, Qingxiao Ma, Sheng‐Cai Shi
article en

Abstract

Abstract We present the contribution of x-ray incident-position dependence on the absorber to the energy resolution of Ti/Au transition-edge sensors (TESs). The pulse height varies with the position due to insufficient thermal conductivity and geometry of the absorber that degrades the measured energy resolution. We develop a three-dimensional (3D) electro-thermal simulation model and thoroughly study the position dependent contribution to energy resolution (Δ E p ) for two presentative absorber structures: an absorber directly deposited on the center of TES sensor (design A) and an absorber cantilevered on the TES sensor by several stems (design B). For design A with a 30 μm × 40 μm Au absorber Δ E p is found to be 9.4 eV, while it is reduced to 1.35 eV for design B with a 100 μm × 100 μm Au absorber. Although the contribution of position dependence is relatively small, this study facilitates further optimization of the absorber structure to achieve enhanced energy resolution.

Chinese Physics BVol. 35(3)
Purple Mountain Observatory (CN)
Openalex Percentile: Top 72%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.