Using the latent diffusion model to enhance time-resolved laser speckle contrast imaging (TR-LSCI) of cerebral blood flow

Continuous monitoring of cerebral blood flow (CBF) with high spatiotemporal resolution and depth sensitivity is essential for accurate diagnosis and effective management of neurological disorders. Although conventional laser speckle contrast imaging (LSCI) enables widefield, high-resolution CBF mapping, its limited penetration depth and signal integration across all tissue layers hinder depth-resolved imaging. To address these limitations, we developed an advanced time-resolved LSCI (TR-LSCI) system that employs picosecond-pulsed laser illumination and a customized SPAD512<sup>2</sup> camera operating in gated mode, enabling noncontact, widefield, and depth-sensitive CBF imaging. However, photon scattering and diffusive noise still degrade image quality, particularly at greater depths. To overcome this challenge, we incorporated a multiscale latent diffusion model (LTDiff++) into the TR-LSCI analysis pipeline to suppress photon diffusion noise. Trained and validated using overlapping image patches from head-simulating phantoms and neonatal rat CBF images with high-quality ground truth references, LTDiff++ effectively suppressed photon diffusion noise while preserving structural and vascular features at greater imaging depths. Moreover, in vivo studies demonstrated that LTDiff++ maintained image quality using only 5-frame averaging, reducing acquisition time by a factor of 20 compared to the conventional 100-frame averaging approach without deep learning enhancement. The integrated TR-LSCI and LTDiff++ framework thus enables robust, high-speed, and depth-resolved imaging of cerebral hemodynamics, offering a promising platform for preclinical research and future clinical applications in bedside neuroimaging and patient monitoring.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-08-15
DOI
https://doi.org/10.1364/boe.567377
Citations
1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using the latent diffusion model to enhance time-resolved laser speckle contrast imaging (TR-LSCI) of cerebral blood flow

Mehrana Mohtasebi, Edoardo Charbon, Rabeya Tus Sadia, Faraneh Fathi et al.
1 citations
Biomedical Optics Express
Optical Imaging and Spectroscopy Techniques
1.36
article

Using the latent diffusion model to enhance time-resolved laser speckle contrast imaging (TR-LSCI) of cerebral blood flow

Mehrana Mohtasebi, Edoardo Charbon, Rabeya Tus Sadia, Faraneh Fathi, Claudio Bruschini, Guoqiang Yu, Paul Moş, Lei Chen, Jin Chen
article en
1 citations

Abstract

Continuous monitoring of cerebral blood flow (CBF) with high spatiotemporal resolution and depth sensitivity is essential for accurate diagnosis and effective management of neurological disorders. Although conventional laser speckle contrast imaging (LSCI) enables widefield, high-resolution CBF mapping, its limited penetration depth and signal integration across all tissue layers hinder depth-resolved imaging. To address these limitations, we developed an advanced time-resolved LSCI (TR-LSCI) system that employs picosecond-pulsed laser illumination and a customized SPAD512<sup>2</sup> camera operating in gated mode, enabling noncontact, widefield, and depth-sensitive CBF imaging. However, photon scattering and diffusive noise still degrade image quality, particularly at greater depths. To overcome this challenge, we incorporated a multiscale latent diffusion model (LTDiff++) into the TR-LSCI analysis pipeline to suppress photon diffusion noise. Trained and validated using overlapping image patches from head-simulating phantoms and neonatal rat CBF images with high-quality ground truth references, LTDiff++ effectively suppressed photon diffusion noise while preserving structural and vascular features at greater imaging depths. Moreover, in vivo studies demonstrated that LTDiff++ maintained image quality using only 5-frame averaging, reducing acquisition time by a factor of 20 compared to the conventional 100-frame averaging approach without deep learning enhancement. The integrated TR-LSCI and LTDiff++ framework thus enables robust, high-speed, and depth-resolved imaging of cerebral hemodynamics, offering a promising platform for preclinical research and future clinical applications in bedside neuroimaging and patient monitoring.

Biomedical Optics ExpressVol. 16(10)
University of Kentucky (US), University of Alabama at Birmingham (US), ​Advanced Systems Technology (United States) (US), École Polytechnique Fédérale de Lausanne (CH)
Openalex Percentile: Top 17%
Optical Imaging and Spectroscopy Techniques
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.