Small-Signal Stability Analysis of Converter-Interfaced Systems in DC Voltage Timescale Based on Amplitude/Frequency Operating Points

The oscillations induced by voltage source converters (VSCs) in DC voltage timescale dynamics pose significant challenges to the safe and stable operation of VSC-dominated power systems. However, previous studies have conducted simplified analyses without fully understanding the fundamental roles of different timescale control loops in converter-interfaced systems. In light of this, this study first identifies the key state variables and operating points that directly characterize the energy storage levels of devices and networks in AC systems. A model for the converter-interfaced system is then established in the specified DC voltage timescale. The key contribution of this work is the proposal of an analytical framework that decomposes system stability into self-stabilizing (Self-stable) and externally coupled stabilizing (En-stable) paths based on internal voltage amplitude and frequency, aiming to reveal the physical mechanisms behind internal voltage amplitude and frequency oscillations in DC voltage timescale dynamics. Based on this framework, the Self-stable path and En-stable path of the internal voltage amplitude/frequency of converter-interfaced systems are derived. This novel analytical method mathematically decouples the stability of a single variable into a direct self-influence path and an indirect path coupled through other system variables. Subsequently, the causes of internal voltage amplitude/frequency oscillations in the specified voltage timescale are explained using the Self-stability and En-stability analysis method. A key finding of this study is that the stability of the internal voltage amplitude and frequency exhibits a dual relationship: for amplitude stability, the Self-stable path is stabilizing, whereas the coupled path is destabilizing; for frequency stability, the roles are reversed. Finally, the results are verified through simulations.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-08-15
DOI
https://doi.org/10.3390/pr13082583
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Small-Signal Stability Analysis of Converter-Interfaced Systems in DC Voltage Timescale Based on Amplitude/Frequency Operating Points

Jiabing Hu, Jin Lv, Sicheng Wang
Processes
Microgrid Control and Optimization
article

Small-Signal Stability Analysis of Converter-Interfaced Systems in DC Voltage Timescale Based on Amplitude/Frequency Operating Points

Jiabing Hu, Jin Lv, Sicheng Wang
article en

Abstract

The oscillations induced by voltage source converters (VSCs) in DC voltage timescale dynamics pose significant challenges to the safe and stable operation of VSC-dominated power systems. However, previous studies have conducted simplified analyses without fully understanding the fundamental roles of different timescale control loops in converter-interfaced systems. In light of this, this study first identifies the key state variables and operating points that directly characterize the energy storage levels of devices and networks in AC systems. A model for the converter-interfaced system is then established in the specified DC voltage timescale. The key contribution of this work is the proposal of an analytical framework that decomposes system stability into self-stabilizing (Self-stable) and externally coupled stabilizing (En-stable) paths based on internal voltage amplitude and frequency, aiming to reveal the physical mechanisms behind internal voltage amplitude and frequency oscillations in DC voltage timescale dynamics. Based on this framework, the Self-stable path and En-stable path of the internal voltage amplitude/frequency of converter-interfaced systems are derived. This novel analytical method mathematically decouples the stability of a single variable into a direct self-influence path and an indirect path coupled through other system variables. Subsequently, the causes of internal voltage amplitude/frequency oscillations in the specified voltage timescale are explained using the Self-stability and En-stability analysis method. A key finding of this study is that the stability of the internal voltage amplitude and frequency exhibits a dual relationship: for amplitude stability, the Self-stable path is stabilizing, whereas the coupled path is destabilizing; for frequency stability, the roles are reversed. Finally, the results are verified through simulations.

ProcessesVol. 13(8)
Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 74%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.