Normal and reverse flow injection- spectrophotometric determination of doxycycline hyclate in bulk and pharmaceutical samples

The present paper reports the development and validation of an analytical method for doxycycline hyclate (DOX) quantification in pure and dosage forms by normal and reverse flow injection analysis (FIA) techniques. Two types of FIA approaches were employed to automate a diazotization coupling reaction of DOX with diazotized benzidine dihydrochloride. Red azo dye was formed rapidly and measured at maximum wavelength of 488 nm. Calibration curves were prepared over different DOX concentrations with linearity ranges of 10-250 and 1-180 µg/mL for normal and reverse FIA systems respectively with the limits of detection of 2.95 and 0.46 µg/mL and limits of quantitation of 9.83 and 1.55 µg/mL, respectively. The developed approaches were then used to determine DOX in pharmaceutical dosage forms with high percentage recoveries and low %RSD. In concordance with the standard method, the proposed techniques demonstrated rapid detection and applicability in pharmaceutical analysis.

Authors

Publication Details

Journal
Baghdad Science Journal
Published
2025-08-15
DOI
https://doi.org/10.21123/2411-7986.5016
Citations
1
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Normal and reverse flow injection- spectrophotometric determination of doxycycline hyclate in bulk and pharmaceutical samples

Hind Hadi, Tabarak Mohammed
1 citations
Baghdad Science Journal
Antibiotics Pharmacokinetics and Efficacy
1.39
article

Normal and reverse flow injection- spectrophotometric determination of doxycycline hyclate in bulk and pharmaceutical samples

Hind Hadi, Tabarak Mohammed
article en
1 citations

Abstract

The present paper reports the development and validation of an analytical method for doxycycline hyclate (DOX) quantification in pure and dosage forms by normal and reverse flow injection analysis (FIA) techniques. Two types of FIA approaches were employed to automate a diazotization coupling reaction of DOX with diazotized benzidine dihydrochloride. Red azo dye was formed rapidly and measured at maximum wavelength of 488 nm. Calibration curves were prepared over different DOX concentrations with linearity ranges of 10-250 and 1-180 µg/mL for normal and reverse FIA systems respectively with the limits of detection of 2.95 and 0.46 µg/mL and limits of quantitation of 9.83 and 1.55 µg/mL, respectively. The developed approaches were then used to determine DOX in pharmaceutical dosage forms with high percentage recoveries and low %RSD. In concordance with the standard method, the proposed techniques demonstrated rapid detection and applicability in pharmaceutical analysis.

Baghdad Science JournalVol. 22(8)
Openalex Percentile: Top 17%
Antibiotics Pharmacokinetics and Efficacy
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Normal and reverse flow injection- spectrophotometric determination of doxycycline hyclate in bulk and pharmaceutical samples — Hind Hadi, Tabarak Mohammed · Baghdad Science Journal (2025) | TGRS Research Map | TGRS