Power system planning using optimally designed transmission lines

Over the past several decades, transmission lines, the primary infrastructure for transporting electric energy across power systems, have largely maintained their traditional designs, despite significant shifts in supply and demand dynamics. The inherent operational limitations of these conventional designs continue to be a major constraint on grid loadability and are expected to remain so in the foreseeable future. To address this challenge, we propose the use of unconventional transmission lines optimally designed with enhanced power transfer capabilities, known as high-surge-impedance loading (HSIL) lines. The proposed HSIL configuration achieves a surge impedance loading of 1354.72 MW, representing a 41.04 % increase over that of conventional 500 kV lines with equivalent conductor weight and cross-sectional area. The impact of these lines on the planning of large-scale power systems is assessed through detailed transmission expansion planning (TEP) studies. Using a 17-bus 500 kV test system in three different loading scenarios, each analyzed under normal and N-1 contingency conditions, we compare the performance of conventional versus HSIL lines to connect a new load to a new location. Comprehensive economic analysis reveals that the implementation of HSIL lines results in substantial cost savings, thus presenting a technically robust and economically attractive solution for future power system planning. • Unconventional line design boosts SIL by 41% and reduces line width by 2.14×. • Maintains same conductor cross-section and weight as conventional 500 kV lines. • TEP study: Unconventional HSIL line needs fewer lines and bays than conventional, reducing costs. • Smaller Right-of-Way lowers environmental impact and land acquisition costs. • Comprehensive TEP study confirms major savings with unconventional vs. conventional lines.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2025-08-21
DOI
https://doi.org/10.1016/j.egyr.2025.08.026
Citations
1
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power system planning using optimally designed transmission lines

Mona Ghassemi, Bhuban Dhamala
1 citations
Energy Reports
Optimal Power Flow Distribution
0.73
article

Power system planning using optimally designed transmission lines

Mona Ghassemi, Bhuban Dhamala
article en
1 citations

Abstract

Over the past several decades, transmission lines, the primary infrastructure for transporting electric energy across power systems, have largely maintained their traditional designs, despite significant shifts in supply and demand dynamics. The inherent operational limitations of these conventional designs continue to be a major constraint on grid loadability and are expected to remain so in the foreseeable future. To address this challenge, we propose the use of unconventional transmission lines optimally designed with enhanced power transfer capabilities, known as high-surge-impedance loading (HSIL) lines. The proposed HSIL configuration achieves a surge impedance loading of 1354.72 MW, representing a 41.04 % increase over that of conventional 500 kV lines with equivalent conductor weight and cross-sectional area. The impact of these lines on the planning of large-scale power systems is assessed through detailed transmission expansion planning (TEP) studies. Using a 17-bus 500 kV test system in three different loading scenarios, each analyzed under normal and N-1 contingency conditions, we compare the performance of conventional versus HSIL lines to connect a new load to a new location. Comprehensive economic analysis reveals that the implementation of HSIL lines results in substantial cost savings, thus presenting a technically robust and economically attractive solution for future power system planning. • Unconventional line design boosts SIL by 41% and reduces line width by 2.14×. • Maintains same conductor cross-section and weight as conventional 500 kV lines. • TEP study: Unconventional HSIL line needs fewer lines and bays than conventional, reducing costs. • Smaller Right-of-Way lowers environmental impact and land acquisition costs. • Comprehensive TEP study confirms major savings with unconventional vs. conventional lines.

Energy ReportsVol. 14
Zero Emissions Resource Organisation (NO)
National Science Foundation
Affordable and clean energy
Openalex Percentile: Top 24%
Optimal Power Flow Distribution
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Power system planning using optimally designed transmission lines — Mona Ghassemi, Bhuban Dhamala · Energy Reports (2025) | TGRS Research Map | TGRS